DEAN PORTABLE MICRO-FLO OIL FILTRATION SYSTEMS

CHAPTER 5: CLEANING AND MAINTENANCE

5.1 General

Cleaning operations fall into three general categories:

??Wiping unit clean after each filter session;

??Cleaning, changing filter paper and preparing the unit for the next day’s business.

??Weekly cleaning to remove oil deposits and other particles that were previously missed.

WARNING

Do not use water jets to clean this equipment.

CAUTION

Never operate the filter unit unless cooking oil is at operating temperature.

5.2 Each Filter Use

Every time your Portable Filter System is used:

??Wash down the insides of the filter pan with hot oil.

??Change the top filter paper sheet after each filter session or at the end of the day. Scrape sediment from the top sheet after each frypot is filtered within a filter session.

??Wipe up any oil which may have splashed or spilled.

??Wipe all exterior surfaces of the filter unit.

CAUTION

Do not run water or boil-out solution through the filtration system. Doing so will cause irreparable damage to the pump, and the warranty will be voided.

5-1

Image 19
Contents MF90 Series Page Table of Contents Ordering Parts Service InformationAfter Purchase Safety InformationGeneral Rating Plate Pre-InstallationUnpacking the Filter System Assembling The Filter System Filter Paper ConfigurationFilter Paper Configuration Wand Filter Preparation Filtering ToolsChanging Filter Paper Changing Filter Paper Changing Filter Paper Unit Operation Unit Operation Unit Operation Unit Operation Each Filter Use Weekly Daily- Close Of BusinessPlugged Lines Operating ProblemsTroubleshooting Flowcharts Filter Pump Fails To Pump Oil Rate Of Oil Return Slowing Blockage Between Filter Pan and Flex-Hose Valve MF90 Filter Wiring AU Wiring DiagramsMF-90/65, U and AU Configuration Dean Portable MICRO-FLO OIL Filtration Systems Parts ListComponent MF-90/65, U and AU Configuration MF-90/80, 80-LP, 110, 126, 160 and 172 Series, U and AU Configurations110 Series Only Component Tubing Assembly 80, 80-LP, 126 and 160 Series Service Hotline