Frymaster MF90 Series manual Rating Plate, Pre-Installation

Page 7

2.1 General (cont.)

The used oil may be drained by gravity from the fryer into the filter pan, or removed from the fryer by use of a suction/return hose, according to model. The oil is pumped back into the fryer vessel using the same suction/return hose.

Oil or shortening is filtered through replaceable filter paper. Filter powder, which enhances the filtering process, is distributed over the paper prior to filtering.

All units are shipped completely assembled with accessories packed inside the frypots. All units are adjusted, tested and inspected at the factory before shipment.

CAUTION

The on-site supervisor is responsible for ensuring that operators are made aware of the inherent dangers of operating a hot oil filter system, particularly the aspects of oil filtration, and drain ing/cleaning procedures.

A7-amp (115V-domestic), or 5-amp (230V- international) circuit breaker installed on the filter unit switches the power OFF if an overload occurs.

NOTE: If the circuit breaker is triggered, depress the reset button to activate the circuit after the failure has been detected and repaired.

2.2 Rating Plate

Information on the rating plate includes model and serial numbers, as well as electrical requirements. Have the rating plate information handy when communicating with the factory about a unit or requesting special parts or information. Without this information, proper identification of the unit cannot be confirmed.

2.3 Pre-Installation

NOTE: Failure to use qualified service personnel will void the Dean warranty.

A.Standards: Use of this filter unit must be in accordance with all applicable state and local codes.

B.Electrical Connections: Domestic MF90 filter units require a 115V 60 Hz., 15 amp electrical supply. Units are equipped with a grounded male receptacle for use with a flexible six- foot, 16-3 SJT power cord set. If an extension cord is required, it must be a three-conductor, grounded power cord of at least 16 gauge.

2-2

Image 7
Contents MF90 Series Page Table of Contents Ordering Parts Service InformationAfter Purchase Safety InformationGeneral Rating Plate Pre-InstallationUnpacking the Filter System Assembling The Filter System Filter Paper ConfigurationFilter Paper Configuration Wand Filter Preparation Filtering ToolsChanging Filter Paper Changing Filter Paper Changing Filter Paper Unit Operation Unit Operation Unit Operation Unit Operation Each Filter Use Weekly Daily- Close Of BusinessPlugged Lines Operating ProblemsTroubleshooting Flowcharts Filter Pump Fails To Pump Oil Rate Of Oil Return Slowing Blockage Between Filter Pan and Flex-Hose Valve MF90 Filter Wiring AU Wiring DiagramsMF-90/65, U and AU Configuration Dean Portable MICRO-FLO OIL Filtration Systems Parts ListComponent MF-90/65, U and AU Configuration MF-90/80, 80-LP, 110, 126, 160 and 172 Series, U and AU Configurations110 Series Only Component Tubing Assembly 80, 80-LP, 126 and 160 Series Service Hotline