Frymaster MF90 Series manual Assembling The Filter System, Filter Paper Configuration

Page 9

DEAN PORTABLE MICRO-FLO OIL FILTRATION SYSTEMS

CHAPTER 3: INSTALLATION INSTRUCTIONS

3.1 Assembling The Filter System

On initial installation and before each use, remove all loose parts from the filter, wash the filter pan and all accessories in hot, soapy water and dry thoroughly.

WARNING!

Water or boil-out solution MUST not be allowed to drain into the filter pan or

filter system. Irreversible damage will result if water is allowed into the

system, and the warranty will be voided.

The MF90 filtration system uses a filter support grid, two sheets of filter paper and a hold- down ring to secure the filter paper in place.

3.1.1 Filter Paper Configuration

See illustration for proper assembly.

1.Filter Pan Cover

2.Hold-Down Ring

3.Filter Paper (2 sheets)

4.Screen/Support Grid

5.Filter Pan Assembly

5

4

3

2

1

A.First, place the support grid in the bottom of filter pan.

B.Put two filter paper sheets on top of the support grid. Be sure the paper covers the whole filter pan bottom.

C.Position the hold-down ring on top of the filter papers and latch the hold-down ring and filter papers securely against the filter pan bottom, forming a tight seal.

3-1

Image 9
Contents MF90 Series Page Table of Contents Ordering Parts Service InformationAfter Purchase Safety InformationGeneral Rating Plate Pre-InstallationUnpacking the Filter System Assembling The Filter System Filter Paper ConfigurationFilter Paper Configuration Wand Filtering Tools Filter PreparationChanging Filter Paper Changing Filter Paper Changing Filter Paper Unit Operation Unit Operation Unit Operation Unit Operation Each Filter Use Weekly Daily- Close Of BusinessPlugged Lines Operating ProblemsTroubleshooting Flowcharts Filter Pump Fails To Pump Oil Rate Of Oil Return Slowing Blockage Between Filter Pan and Flex-Hose Valve MF90 Filter Wiring AU Wiring DiagramsMF-90/65, U and AU Configuration Dean Portable MICRO-FLO OIL Filtration Systems Parts ListComponent MF-90/65, U and AU Configuration MF-90/80, 80-LP, 110, 126, 160 and 172 Series, U and AU Configurations110 Series Only Component Tubing Assembly 80, 80-LP, 126 and 160 Series Service Hotline