Frymaster MF90 Series manual Filter Pump Fails To Pump Oil

Page 23

Filter Pump Fails To Pump Oil

Filter pump fails to pump oil.

If filter unit has a heater, turn heater ON and allow to heat for 20 minutes.

Disconnect flexible oil return

hose. Make sure it is cool before handling. Try blowing air through the hose.

 

 

 

Submerge hose in very hot water,

Can you blow

 

 

keeping the water out of the hose.

No

 

Water in the hose will cause severe

air through it?

 

 

 

splattering when hot oil is circulated

 

 

 

 

 

 

through the hose.

 

 

 

 

Yes

Insert flexible oil return hose into filter pan and turn pump motor ON.

Once shortening has had time to soften, reconnect hose to

filter pump.

Blockage is between bottom of the filter

pan and the flexible hose quick

Does oil flow through oil No disconnect. Go to "Blockage Between return hose?

Filter Pan and Flex Hose Valve.

Yes

Proceed with normal

operations.

6-3

Image 23
Contents MF90 Series Page Table of Contents Ordering Parts Service InformationAfter Purchase Safety InformationGeneral Rating Plate Pre-InstallationUnpacking the Filter System Assembling The Filter System Filter Paper ConfigurationFilter Paper Configuration Wand Changing Filter Paper Filtering ToolsFilter Preparation Changing Filter Paper Changing Filter Paper Unit Operation Unit Operation Unit Operation Unit Operation Each Filter Use Weekly Daily- Close Of BusinessPlugged Lines Operating ProblemsTroubleshooting Flowcharts Filter Pump Fails To Pump Oil Rate Of Oil Return Slowing Blockage Between Filter Pan and Flex-Hose Valve MF90 Filter Wiring AU Wiring DiagramsMF-90/65, U and AU Configuration Dean Portable MICRO-FLO OIL Filtration Systems Parts ListComponent MF-90/65, U and AU Configuration MF-90/80, 80-LP, 110, 126, 160 and 172 Series, U and AU Configurations110 Series Only Component Tubing Assembly 80, 80-LP, 126 and 160 Series Service Hotline