Frymaster MF90 Series manual Filtering Tools, Filter Preparation, Changing Filter Paper

Page 12

4.2 Filtering Tools

These tools are not required, but are recommended to make the filtering task easier.

A.Measuring Cup : Used to measure eight ounces by volume of filter powder.

B.Scrub Brush: To clean sediment and residue from the filter pan and fry vessel.

C.Appropriate Clothing.

4.3Filter Preparation

1.Position the MF-90 filter next to the fryer. Remove filter pan lid and position filter unit under frypot drain- valve extension

2.Ensure the filter power switch is in “OFF” position prior to connecting to power supply.

3.Plug power cord into electrical outlet. The filter unit is ready for filtering. If equipped, turn on heater switch to allow pan to preheat. After filtering, follow instructions in Section 4.4, Changing Filter Paper.

CAUTION

The crumb tray (if equipped) in portable filter systems must be emptied into a

fireproof container at the end of frying operations each day. Some food particles can spontaneously combust if left soaking in certain shortening material.

4.4 Changing Filter Paper

The top sheet of filter paper should be replaced after each filter session, and most certainly at the beginning of each workday. If filter paper is replaced once per day, excess sediment should be scraped from the top filter paper after each frypot is filtered (see photo). Filter at closing if possible. This ensures the oil/shortening is at proper filtering temperature.

Scrape excess sediment from top filter paper sheet after filtering.

4-2

Image 12
Contents MF90 Series Page Table of Contents Service Information Ordering PartsSafety Information After PurchaseGeneral Pre-Installation Rating PlateUnpacking the Filter System Filter Paper Configuration Assembling The Filter SystemFilter Paper Configuration Wand Filtering Tools Filter PreparationChanging Filter Paper Changing Filter Paper Changing Filter Paper Unit Operation Unit Operation Unit Operation Unit Operation Each Filter Use Daily- Close Of Business WeeklyOperating Problems Plugged LinesTroubleshooting Flowcharts Filter Pump Fails To Pump Oil Rate Of Oil Return Slowing Blockage Between Filter Pan and Flex-Hose Valve Wiring Diagrams MF90 Filter Wiring AUDean Portable MICRO-FLO OIL Filtration Systems Parts List MF-90/65, U and AU ConfigurationComponent MF-90/65, U and AU Configuration Configurations MF-90/80, 80-LP, 110, 126, 160 and 172 Series, U and AU110 Series Only Component Tubing Assembly 80, 80-LP, 126 and 160 Series Service Hotline