Maintenance
Panel Light | Storage Drawer |
To replace panel light bulb:
Grasp the top trim of the back panel with your thumbs under the front edge and pull outward while lifting the trim. Remove the bulb and replace it with an 18 watt fluorescent tube. Snap the top trim back into place and restore the power. Reset the
clock. | _ |
| :_ |
Oven Light
The storage drawer can be removed to allow you to clean under the range.
To remove:
1.Empty drawer and pull out to the first stop position.
2.Lift up the front of the drawer.
3.Pull out to the second stop position.
4.Grasp sides and lift drawer up and out.
To replace:
1. Fit the ends of the drawerglides into the rails in the range.
2.Lift up front of drawer and gently push in to the first stop position.
3. Lift drawer up again and push until drawer is closed.
Leveling Legs
To replace oven light bulb:
1. When oven is cool, hold bulb cover in place, then slide
| wire retainer off cover. NOTE: Bulb cover will fall if not | |||||
| held in place while re- | BULBCOVER |
| |||
| moving wire retainer. |
| __ |
| ||
| Remove bulb | cover |
| |||
2.and light bulb. |
|
| //'/(_Q@_ | ) | ||
3. | Replace with | a 40 | ( |
| _ | |
| wattappliancebulb. | _ |
|
| ||
4. | Replace bulb | cover |
|
| RETAINER | |
|
|
|
| |||
| and secure with wire retainer, |
| ||||
5. | Reconnect power to range. Reset clock. |
|
The range should be leveled when in- |
| |
stalled. Iftherangeisnotlevel, | tumthe |
|
plastic leveling legs, located | at each |
|
comer of the range, until range | is level. | LEvEuLEGNo |
Convenience | Outlet (Canadian models only) | ||
The convenience | outlet is located | .... |
|
on the lower left side of the | "_4.,S ,J."e | " 4._)."6 | |
backguard. It is useful for small | N |
| |
appliances such as waffle irons. |
|
| |
When using the outlet be sure the |
|
| |
appliance cord does not rest on or |
|
| |
near the surface | element. If the | C_Rcu_rsREAKE_ | |
surface element is turned on, the |
| sw_rcH | |
cord and outlet will be damaged. |
|
|
The convenience outlet circuit breaker may trip if the small appliance plugged into it exceeds 10 amps. To reset the circuit breaker, press the switch located on the lower edge of the backguard. (See illustration.)