Jenn-Air W10197059B Complete Installation, If you need Assistance or Service

Page 11

3-Wire Cable from Home Power Supply to 4-Wire Cable from Cooktop - U.S. only

IMPORTANT: Use the 3-wire cable from power supply where local codes permit connecting the frame-ground conductor to the neutral (white) junction box wire.

A

E

B

F

G

H

C

I

D

A. Cable from home power supply

F. White wire

B. Red wires

G. UL listed wire connector

C. White wire and green (or bare)

H. Black wires

wire (from cooktop)

I. UL listed or CSA approved

D. 4-wire cable from cooktop

conduit connector

E. Junction box

 

1.Connect the 2 black wires together using the UL listed wire connectors.

2.Connect the 2 red wires together using the UL listed wire connectors.

3.Connect the green or bare and white cooktop cable wires to the white (neutral) wire in the junction box using the UL listed wire connectors.

4.Install junction box cover.

Complete Installation

1.Check that all parts are now installed. If there is an extra part, go back through the steps to see which step was skipped.

2.Check that you have all your tools.

3.Dispose of/recycle all packaging materials.

4.Use a mild solution of liquid household cleaner and warm water to clean cooktop before use. Dry thoroughly with a soft cloth. For more information, see the “Cooktop Care” section of the Use and Care Guide.

5.Read “Cooktop Use” in the cooktop Use and Care Guide.

6.Reconnect power.

7.Use the Flow Tester Card provided with your cooktop to check the airflow (see card for step-by-step instructions).

NOTE: If the cooktop does not work after turning on the power, check that a circuit breaker has not tripped or a household fuse has not blown. See “Troubleshooting” section in the Use and Care Guide for further information.

If you need Assistance or Service:

Please reference the “Assistance or Service” section of the Use and Care Guide or contact the dealer from whom you purchased your cooktop.

11

Image 11
Contents 30 76.2 CM and 36 91.4 CM Electric Your safety and the safety of others are very important Cooktop SafetyLocation Requirements Installation RequirementsTools and Parts 36 91.4 cm Cooktop for standard and electric models Cabinet DimensionsFor Best Performance Cutout DimensionsCold Weather Installations Venting RequirementsOption 1 Roof Venting Option 2 Wall Venting Concrete Slab Installations Exhaust Through WallJenn-AirDuct Free Filter Accessory Kit Venting MethodsVent Piece Cm Round Electrical RequirementsCalculating Vent System Length Example vent systemRotate Blower Optional Installation InstructionsInstall Foam Strip Prepare CooktopTo rotate blower motor To rotate blowerElectrical Connection Options Install CooktopIf your home has You will be Go to Section Connecting to Make Electrical ConnectionIf you need Assistance or Service Complete InstallationPage Votre sécurité et celle des autres est très importante Sécurité DE LA Table DE CuissonOutillage et pièces Exigences DinstallationExigences demplacement Dimensions du placard Pour obtenir la meilleure performance Dimensions de l’ouverture à découperInstallations pour régions à climat froid Exigences concernant lévacuationMéthodes dévacuation La trousse accessoire de filtration sans conduit Jenn-AirComposant Conduit de diamètre de 15,2 cm Coude à Pi 0,8 m Spécifications électriquesCalcul de la longueur effective du circuit dévacuation Exemple de circuit dévacuationAvant d’établir la connexion électrique Instructions D’INSTALLATIONInstallation de la bande de mousse Préparation de la table de cuissonPour faire pivoter le moteur du ventilateur Rotation du ventilateur FacultativePour faire pivoter le ventilateur Câblage de la maison Point de Installation de la table de cuissonRaccordement électrique Options de raccordement électriqueSi vous avez besoin dassistance ou de service Achever linstallationPage 2009 10/09 All rights reserved