Jenn-Air W10197059B 36 91.4 cm Cooktop for standard and electric models, Cabinet Dimensions

Page 4

 

A

 

B

H

 

G

F

 

C

 

E

 

D

A. 29³⁄₄" (75.6 cm)

B. 12¹⁄₂" (31.8 cm) centerline of product to edge of burner box C. 12¹⁄₂" (31.8 cm)

D. 28³⁄₈" (73.3 cm)

E.12¹⁄₂" (31.8 cm)

F.2" (5.1 cm) recommended minimum cabinet to motor clearance

G.16³⁄₈" (41.6 cm)

H.4⁵⁄₈" (11.8 cm)

36" (91.4 cm) Cooktop - for standard and electric models

C

A

B

A. Model/serial rating plate location

B. 20⁹⁄₁₆" (52.3 cm)

C. 22" (55.9 cm)

 

A

 

B

H

 

G

 

F

C

 

E

 

D

A.35¹¹⁄₃₂" (89.8 cm)

B.12⁷⁄₈" (32.8 cm) centerline of product to edge of burner box

C.12⁷⁄₈" (32.8 cm)

D.34¹⁄₈" (87.3 cm)

E.12¹⁄₂" (31.8 cm)

F. 2" (5.1 cm) recommended minimum cabinet to motor clearance G. 16³⁄₈" (41.6 cm)

H. 4⁵⁄₈" (11.8 cm)

Cabinet Dimensions

A

D

C B

L FG

E

H

I

KJ

A. 30" (76.2 cm) on 30" (76.2 cm) models 36" (91.4 cm) on 36" (91.4 cm) models

B. Combustible area above countertop (shown by dashed box above)

C. 30" (76.2 cm) minimum clearance between top of cooktop platform and bottom of uncovered wood or metal cabinet (24" [61 cm] minimum clearance if bottom of wood or metal cabinet is covered by not less than ¹⁄₄" [0.6 cm] flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless steel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)

D. 13" (33 cm) recommended upper cabinet depth E. 2" (5.1 cm)

F. 21¹⁄₈" (73.4 cm)

G. 18" (45.7 cm) minimum clearance from upper cabinet to countertop within minimum horizontal clearances to cooktop

H. Junction box or outlet; 12" (30.5 cm) minimum from bottom of countertop

I. Junction box or outlet; 10" (25.4 cm) from right-hand side of cabinet

J. 28⁷⁄₈" (73.4 cm) on 30" (76.2 cm) models 34½" (87.6 cm) on 36" (91.4 cm) models

K. 2½" (6.4 cm) minimum distance to nearest left and right side combustible surface above cooktop

L. 1½" (3.8 cm) minimum clearance between back wall and countertop

NOTES: After making the countertop cutout, some installations may require notching down the base cabinet side walls to clear the cooktop base. To avoid this modification, use a base cabinet with sidewalls wider than the cutout.

A minimum side clearance of 6" (15.2 cm) is recommended between side of cooktop and side wall for maximum ventilation performance.

A minimum clearance of 2" (5.1 cm) is recommended between the motor/blower and cabinet for proper cooling. A

6" (15.2 cm) clearance is recommended for servicing access.

4

Image 4
Contents 30 76.2 CM and 36 91.4 CM Electric Cooktop Safety Your safety and the safety of others are very importantTools and Parts Installation RequirementsLocation Requirements Cabinet Dimensions 36 91.4 cm Cooktop for standard and electric modelsCutout Dimensions Cold Weather InstallationsVenting Requirements For Best PerformanceConcrete Slab Installations Exhaust Through Wall Jenn-AirDuct Free Filter Accessory KitVenting Methods Option 1 Roof Venting Option 2 Wall VentingElectrical Requirements Calculating Vent System LengthExample vent system Vent Piece Cm RoundInstallation Instructions Install Foam StripPrepare Cooktop Rotate Blower OptionalTo rotate blower To rotate blower motorInstall Cooktop If your home has You will be Go to Section Connecting toMake Electrical Connection Electrical Connection OptionsComplete Installation If you need Assistance or ServicePage Sécurité DE LA Table DE Cuisson Votre sécurité et celle des autres est très importanteExigences demplacement Exigences DinstallationOutillage et pièces Dimensions du placard Dimensions de l’ouverture à découper Installations pour régions à climat froidExigences concernant lévacuation Pour obtenir la meilleure performanceLa trousse accessoire de filtration sans conduit Jenn-Air Méthodes dévacuationSpécifications électriques Calcul de la longueur effective du circuit dévacuationExemple de circuit dévacuation Composant Conduit de diamètre de 15,2 cm Coude à Pi 0,8 mInstructions D’INSTALLATION Installation de la bande de moussePréparation de la table de cuisson Avant d’établir la connexion électriquePour faire pivoter le ventilateur Rotation du ventilateur FacultativePour faire pivoter le moteur du ventilateur Installation de la table de cuisson Raccordement électriqueOptions de raccordement électrique Câblage de la maison Point deAchever linstallation Si vous avez besoin dassistance ou de servicePage 2009 10/09 All rights reserved