Jenn-Air W10197059B Electrical Requirements, Calculating Vent System Length, Example vent system

Page 7

Calculating Vent System Length

To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.

Vent Piece

6" (15.2 cm) Round

45° elbow

2.5 ft

 

(0.8 m)

 

 

90° elbow

5.0 ft

 

(1.5 m)

 

 

6" (15.2 cm)

0.0 ft

wall cap

(0.0 m)

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

4.5 ft

to 6" (15.2 cm) transition

(1.4 m)

 

 

6" (15.2 cm) to 3¹⁄₄" x 10"

1 ft

(8.3 cm x 25.4 cm) transition

(0.3 m)

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

5.0 ft

to 6" (15.2 cm) 90° elbow

(1.5 m)

transition

 

 

 

6" (15.2 cm) to 3¹⁄₄" x 10"

5.0 ft

(8.3 cm x 25.4 cm) 90° elbow

(1.5 m)

transition

 

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

5.0 ft

90° elbow

(1.5 m)

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

12.0 ft

flat elbow

(3.7 m)

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

0.0 ft

wall cap

(0.0 m)

 

 

Example vent system

wall cap

90˚ elbow

 

 

 

 

 

 

 

 

 

6 ft (1.8 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 ft

 

 

 

 

 

(0.6 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1- 90° elbow

= 5 ft (1.5 m)

8 ft (2.4 m) straight

= 8 ft (2.4 m)

1 - wall cap

= 0 ft (0 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

System length

= 13 ft (3.9 m)

NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that greatly reduce performance.

Electrical Requirements

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use 8 gauge copper wire.

Electrically ground cooktop.

Failure to follow these instructions can result in death, fire, or electrical shock.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path and wire gauge are in accordance with local codes.

Check with a qualified electrical installer if you are not sure the cooktop is properly grounded.

Make sure that the electrical connection and wire size are adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. O-M91-latest edition, and all local codes and ordinances.

A copy of the above code standards can be obtained from:

National Fire Protection Association One Batterymarch Park

Quincy, MA 02269

CSA International

8501 East Pleasant Valley Road Cleveland, OH 44131-5575

7

Image 7
Contents 30 76.2 CM and 36 91.4 CM Electric Your safety and the safety of others are very important Cooktop SafetyTools and Parts Installation RequirementsLocation Requirements 36 91.4 cm Cooktop for standard and electric models Cabinet DimensionsFor Best Performance Cutout DimensionsCold Weather Installations Venting RequirementsOption 1 Roof Venting Option 2 Wall Venting Concrete Slab Installations Exhaust Through WallJenn-AirDuct Free Filter Accessory Kit Venting MethodsVent Piece Cm Round Electrical RequirementsCalculating Vent System Length Example vent systemRotate Blower Optional Installation InstructionsInstall Foam Strip Prepare CooktopTo rotate blower motor To rotate blowerElectrical Connection Options Install CooktopIf your home has You will be Go to Section Connecting to Make Electrical ConnectionIf you need Assistance or Service Complete InstallationPage Votre sécurité et celle des autres est très importante Sécurité DE LA Table DE CuissonExigences demplacement Exigences DinstallationOutillage et pièces Dimensions du placard Pour obtenir la meilleure performance Dimensions de l’ouverture à découperInstallations pour régions à climat froid Exigences concernant lévacuationMéthodes dévacuation La trousse accessoire de filtration sans conduit Jenn-AirComposant Conduit de diamètre de 15,2 cm Coude à Pi 0,8 m Spécifications électriquesCalcul de la longueur effective du circuit dévacuation Exemple de circuit dévacuationAvant d’établir la connexion électrique Instructions D’INSTALLATIONInstallation de la bande de mousse Préparation de la table de cuissonPour faire pivoter le ventilateur Rotation du ventilateur FacultativePour faire pivoter le moteur du ventilateur Câblage de la maison Point de Installation de la table de cuissonRaccordement électrique Options de raccordement électriqueSi vous avez besoin dassistance ou de service Achever linstallationPage 2009 10/09 All rights reserved