Typical flexible connection.
| A. Manifold entrance | |
| B. Gas pressure regulator | |
| C. Use | |
A | D. Adapter (must have ½" male pipe | |
| thread) | |
B | E. Flexible connector | |
F. Adapter | ||
| ||
C | G. Use | |
H. Manual gas shutoff valve | ||
D | ||
I. ½" or ¾" gas pipe | ||
|
E
F
G
H
I
4.Install the pressure regulator with the arrow pointing up toward the bottom of the cooktop base and in a position where you can reach the regulator access cap.
B
A
C
D
A. Access cap
B. Rear of cooktop
C. Gas pressure regulator
D. Up arrow. Regulator must be installed with arrow pointing up to cooktop bottom.
IMPORTANT: All connections must be
Use only
Do not use TEFLON® tape. You will need to determine the fittings required depending on your installation.
Complete Connection
1.Open the manual shutoff valve in the gas supply line. The valve is open when the handle is parallel to the gas pipe.
A
B
A. Closed valve
B. Open valve
2.Test all connections by brushing on an approved noncorrosive
3.Remove surface burner caps and grates from parts package. Align notches in burner caps with pins in burner base. Burner caps should be level when properly positioned. If burner caps are not properly positioned, surface burners will not light.
Place burner grates over burners and caps.
A
D
B
E
C
A. Burner cap
B. Burner ports
C. Burner base
D. Gas tube opening
E. Igniter head
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
4.Plug into a grounded 3 prong outlet.