Jenn-Air W10197058B Electrical Requirements, Calculating Vent System Length, Example vent system

Page 7

Calculating Vent System Length

To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.

Vent Piece

6" (15.2 cm) Round

45° elbow

2.5 ft

 

(0.8 m)

90° elbow

5.0 ft

 

(1.5 m)

6" (15.2 cm)

0.0 ft

wall cap

(0.0 m)

Example vent system

wall cap

90˚ elbow

6 ft (1.8 m)

2ft

(0.6 m)

1- 90° elbow

= 5 ft (1.5 m)

8 ft (2.4 m) straight

= 8 ft (2.4 m)

1 - wall cap

= 0 ft (0 m)

 

 

System length

= 13 ft (3.9 m)

NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that greatly reduce performance.

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

4.5 ft

to 6" (15.2 cm) transition

(1.4 m)

 

 

6" (15.2 cm) to 3¹⁄₄" x 10"

1 ft

(8.3 cm x 25.4 cm) transition

(0.3 m)

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

5.0 ft

to 6" (15.2 cm) 90° elbow

(1.5 m)

transition

 

 

 

6" (15.2 cm) to 3¹⁄₄" x 10"

5.0 ft

(8.3 cm x 25.4 cm) 90° elbow

(1.5 m)

transition

 

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

5.0 ft

90° elbow

(1.5 m)

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

12.0 ft

flat elbow

(3.7 m)

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

0.0 ft

wall cap

(0.0 m)

 

 

Electrical Requirements

IMPORTANT: The cooktop must be electrically grounded in accordance with local codes and ordinances, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.

This cooktop is equipped with an electronic ignition system that will not operate if plugged into an outlet that is not properly polarized.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association

One Batterymarch Park

Quincy, MA 02269

CSA International

8501 East Pleasant Valley Road

Cleveland, Ohio 44131-5575

A 120 volt, 60 Hz, AC only, 15-amp, fused electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this cooktop be provided.

Electronic ignition systems operate within wide voltage limits, but proper grounding and polarity are necessary. Check that the outlet provides 120-volt power and is correctly grounded.

The wiring diagrams are provided with this cooktop. See “Wiring Diagrams” on a separate sheet. The wiring diagrams are located on the left underside of the cooktop base.

7

Image 7
Contents Cooktop Safety Cooktop Installation InstructionsWhat to do if YOU Smell GAS Tools and Parts Installation RequirementsLocation Requirements 36 91.4 cm Cooktop Cabinet DimensionsFor Best Performance Cutout DimensionsCold Weather Installations Venting RequirementsOption 1 Roof Venting Option 2 Wall Venting Concrete Slab Installations Exhaust Through WallJenn-AirDuct Free Filter Accessory Kit Venting MethodsVent Piece Cm Round Electrical RequirementsCalculating Vent System Length Example vent systemGas Pressure Regulator Gas Supply RequirementsType of Gas Gas Supply LineRotate Blower Optional Installation InstructionsInstall Cooktop Gas Supply Pressure TestingTo rotate blower motor Make Gas ConnectionComplete Connection Typical flexible connectionElectronic Ignition System Complete InstallationVotre sécurité et celle des autres est très importante Sécurité DE LA Table DE CuissonExigences demplacement Exigences DinstallationOutillage et pièces Entre le placard et le moteur Dimensions de l’ouverture à découper Dimensions du placardExigences concernant lévacuation Air d’appoint Installations pour régions à climat froidMéthodes dévacuation Pour obtenir la meilleure performanceComposant Conduit de diamètre de 15,2 cm Coude à Pi 0,8 m La trousse accessoire de filtration sans conduit Jenn-AirCalcul de la longueur effective du circuit dévacuation Exemple de circuit dévacuationGaz naturel Spécifications électriquesSpécifications de lalimentation en gaz Type de gazTest de pressurisation de la canalisation de gaz Canalisation de gazDétendeur de gaz Caractéristiques dalimentation du brûleurPour faire pivoter le ventilateur Instructions D’INSTALLATIONInstallation de la table de cuisson Rotation du ventilateur FacultativePour faire pivoter le moteur du ventilateur Raccordement au gazAchever le raccordement Raccordement typique par raccord flexibleAllumage initial et réglages des flammes de gaz Achever linstallationSi vous avez besoin d’assistance ou de service Système dallumage électronique