A
B
CD
E
F
Cabinet Dimensions
A
D
C B
G
I
A. 30" (76.2 cm)
B. 12¹⁵⁄₁₆" (32.9 cm) centerline of cooktop to centerline of gas manifold pipe
C. 4" (10.2 cm)
D. 6¹⁹⁄₃₂" (16.8 cm) E. 18⁷⁄₁₆" (46.8 cm)
H
F.1¹¹⁄₁₆" (4.3 cm) recommended minimum cabinet to motor clearance
G. 12¹⁄₂" (31.8 cm)
H. 14" (35.6 cm)
I. 28¼" (71.4 cm)
L E FG N
H
M
IK
K | J |
| M |
36" (91.4 cm) Cooktop
A
B
C
A. 21½" (54.6 cm)
B. 19¹¹⁄₁₆" (50.0 cm)
C. Model/serial rating plate location
A
B
C | D |
E
|
| F |
|
|
|
| G |
|
|
| H |
|
| ||
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
| I |
|
|
| |||||
A. 36" (91.4 cm) |
|
| |||||||||||||
F. 10³⁄₈" (26.4 cm) | |||||||||||||||
B. 15¾" (40.0 cm) centerline of | recommended minimum | ||||||||||||||
cooktop to centerline of gas | cabinet to motor clearance | ||||||||||||||
manifold pipe | G. 12¹⁄₂" (31.8 cm) | ||||||||||||||
C. 4" (10.2 cm) | H. 13" (33.0 cm) | ||||||||||||||
D. 6¹⁹⁄₃₂" (16.8 cm) | I. 34³⁄₈" (87.3 cm) | ||||||||||||||
E. 18⁷⁄₁₆" (46.8 cm) |
|
|
|
|
|
|
|
|
|
A. 30" | (76.2 cm) on 30" (76.2 cm) models |
36" | (91.4 cm) on 36" (91.4 cm) models |
B. Combustible area above countertop (shown by dashed box above) | |
C. 30" (76.2 cm) minimum clearance between top of cooktop platform | |
and bottom of uncovered wood or metal cabinet (24" [61.0 cm] | |
minimum clearance if bottom of wood or metal cabinet is covered | |
by not less than ¼" [0.6 cm] flame retardant millboard covered with | |
not less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless | |
steel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper) | |
D. 13" | (33.0 cm) recommended upper cabinet depth |
E. 2¹⁄₈" (5.4 cm) |
F. 19¹⁵⁄₁₆" (50.6 cm)
G. 18" (45.7 cm) minimum clearance from upper cabinet to countertop within minimum horizontal clearances to cooktop
H. Junction box or outlet; 12" (30.5 cm) minimum from bottom of countertop
I. Junction box or outlet; 10" (25.4 cm) from
J. 28⁵⁄₈" (72.7cm) on 30" (76.2 cm) models 34¾" (88.3 cm) on 36" (91.4 cm) models
K. 6" (15.2 cm) minimum distance to nearest left and right side combustible surface above cooktop
L. 2" (5.1 cm) minimum clearance between back wall and countertop
M. Gas line opening - Wall: anywhere 6" (15.2 cm) below underside of countertop. Cabinet floor: anywhere within 6" (15.2 cm) of rear wall is recommended.
N. 25" (63.5 cm) depth of countertop
NOTES: After making the countertop cutout, some installations may require notching down the base cabinet side walls to clear the cooktop base. To avoid this modification, use a base cabinet with sidewalls wider than the cutout.
■A minimum side clearance of 6" (15.2 cm) is recommended between side of cooktop and side wall for maximum ventilation performance.
■A minimum clearance of 2" (5.1 cm) is recommended between the motor/blower and cabinet for proper cooling. A 6" (15.2 cm) clearance is recommended for servicing access.
4