Jenn-Air W10197058B Installation Requirements, Tools and Parts, Location Requirements

Page 3

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Tools needed

Tape measure

Pliers

Flat-blade screwdriver

¼" drill bit

Phillips head screwdriver

Jigsaw

Drill

Ratchet with ³⁄₈" socket

Level

Pipe-joint compound

6" (15.2 cm) socket

 

resistant to LP gas

 

Noncorrosive leak-detection

 

extension

Marker or pencil

 

solution

 

 

Parts supplied

Vent grill

Burner caps

Pre-filter

Burner grates

LP conversion kit

Pressure regulator

Parts needed

Metal ducting

Vent clamps

Jenn-Air wall cap

Jenn-Air®6" (15.2 cm) Round Surface Wall Cap Damper Order Part Number A406

Jenn-Air®3¼" x 10" (8.3 x 25.4 cm) Surface Wall Cap Damper Order Part Number A403

To order, see the “Assistance or Service” section of the Use and Care Guide.

Check local codes and consult gas supplier. Check existing gas supply and electrical supply. See “Electrical Requirements” and “Gas Supply Requirements” sections.

It is recommended that all electrical connections be made by a licensed, qualified electrical installer.

The cooktop should be installed in a location away from strong draft areas, such as windows, doors and strong heating vents or fans.

All openings in the wall or floor where cooktop is to be installed must be sealed.

Cabinet opening dimensions that are shown must be used. Given dimensions are minimum clearances.

Grounded electrical supply is required. See “Electrical Requirements” section. Proper gas supply connection must be available. See “Gas Supply Requirements” section.

The cooktop is designed to hang from the countertop by its side or rear flanges.

The gas and electric supply should be located as shown in “Cabinet Dimensions” section so that they are accessible without requiring removal of the cooktop.

Provide cutout in right rear corner of cutout enclosure as shown to provide clearance for gas inlet, power supply cord, and to allow the rating label to be visible.

If cabinet has drawers, drawers will need to be removed and drawer fronts installed on front of cabinet.

IMPORTANT: An undercounter built-in oven cannot be installed under this product.

IMPORTANT: To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage.

Mobile Home - Additional Installation Requirements

The installation of this cooktop must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280). When such standard is not applicable, use the Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A or local codes.

In Canada, the installation of this cooktop must conform with the current standards CAN/CSA-A240-latest edition, or with local codes.

Product Dimensions

30" (76.2 cm) Cooktop

Location Requirements

A

IMPORTANT: Observe all governing codes and ordinances. When

 

installing cooktop, use minimum dimensions given.

 

It is the installer’s responsibility to comply with installation

 

clearances specified on the model/serial rating plate. The

 

model/serial rating plate is located on side of the downdraft

 

plenum.

B

To eliminate the risk of burns or fire by reaching over the

 

heated surface units, cabinet storage space located above the

 

surface units should be avoided. If cabinet storage is to be

 

provided, the risk can be reduced by installing a range hood

 

that projects horizontally a minimum of 5" (12.7 cm) beyond

C

the bottom of the cabinets.

 

A. 21½" (54.6 cm)

B. 19¹¹⁄₁₆" (50.0 cm)

C. Model/serial rating plate location

3

Image 3
Contents Cooktop Safety Cooktop Installation InstructionsWhat to do if YOU Smell GAS Installation Requirements Tools and PartsLocation Requirements 36 91.4 cm Cooktop Cabinet DimensionsFor Best Performance Cutout DimensionsCold Weather Installations Venting RequirementsOption 1 Roof Venting Option 2 Wall Venting Concrete Slab Installations Exhaust Through WallJenn-AirDuct Free Filter Accessory Kit Venting MethodsVent Piece Cm Round Electrical RequirementsCalculating Vent System Length Example vent systemGas Pressure Regulator Gas Supply RequirementsType of Gas Gas Supply LineRotate Blower Optional Installation InstructionsInstall Cooktop Gas Supply Pressure TestingTo rotate blower motor Make Gas ConnectionComplete Connection Typical flexible connectionElectronic Ignition System Complete InstallationVotre sécurité et celle des autres est très importante Sécurité DE LA Table DE CuissonExigences Dinstallation Exigences demplacementOutillage et pièces Entre le placard et le moteur Dimensions du placard Dimensions de l’ouverture à découperExigences concernant lévacuation Air d’appoint Installations pour régions à climat froidMéthodes dévacuation Pour obtenir la meilleure performanceComposant Conduit de diamètre de 15,2 cm Coude à Pi 0,8 m La trousse accessoire de filtration sans conduit Jenn-AirCalcul de la longueur effective du circuit dévacuation Exemple de circuit dévacuationGaz naturel Spécifications électriquesSpécifications de lalimentation en gaz Type de gazTest de pressurisation de la canalisation de gaz Canalisation de gazDétendeur de gaz Caractéristiques dalimentation du brûleurPour faire pivoter le ventilateur Instructions D’INSTALLATIONInstallation de la table de cuisson Rotation du ventilateur FacultativePour faire pivoter le moteur du ventilateur Raccordement au gazAchever le raccordement Raccordement typique par raccord flexibleAllumage initial et réglages des flammes de gaz Achever linstallationSi vous avez besoin d’assistance ou de service Système dallumage électronique