Jenn-Air W10197058B Installation Instructions, Install Cooktop, Rotate Blower Optional

Page 9

Burner Input Requirements

Input ratings shown on the model/serial rating plate are for elevations up to 2,000 ft (609.6 m).

For elevations above 2,000 ft (609.6 m), ratings should be reduced at a rate of 4% for each 1,000 ft (304.8 m) above sea level (not applicable for Canada).

Gas Supply Pressure Testing

Gas supply pressure for testing regulator must be at least

1" water column pressure above the manifold pressure shown on the model/serial rating plate.

Line pressure testing above ½ psi gauge (14" WCP)

The cooktop and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ psi (3.5 kPa).

Line pressure testing at ½ psi gauge (14" WCP) or lower

The cooktop must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi (3.5 kPa).

INSTALLATION INSTRUCTIONS

Install Cooktop

Decide on the final location for the cooktop.

WARNING

Excessive Weight Hazard

Use two or more people to move and install cooktop. Failure to do so can result in back or other injury.

1.Open carton as instructed on product packaging.

2.Remove shipping materials and tape from cooktop.

3.Remove the removable grease filter by lifting the filter out.

4.For island or peninsula installations, go to the “Rotate Blower - Optional” section.

A

A. Removable grease filter

5.Using 2 or more people, remove the cooktop from the carton.

REMEMBER: An undercounter built-in oven cannot be installed under this cooktop.

6.Place cooktop right side up into the cutout.

NOTE: Make sure that the front edge of the cooktop is parallel to the front edge of the countertop. If repositioning is needed, lift entire cooktop up from the cutout to avoid scratching the countertop.

7.Connect blower exhaust scroll to ducting.

8.Use vent clamps to secure the ducting to the blower exhaust scroll.

9.Reinstall grease filter.

10.Reinstall vent grille.

Rotate Blower - Optional

IMPORTANT: The following additional steps must be performed if the product is being installed in peninsula or island cabinetry.

The blower exhaust scroll is shipped from the factory set to exhaust straight out the back of the cabinet through an exterior wall.

D

E

C

E

A

B

F

 

A. Blower exhaust scroll

D. Top label

B. Plenum

E. 10-32 machine nuts (4)

C. Blower motor

F. Motor mounting plate

To rotate blower:

1.Locate the 4 plastic plugs in the plenum bypass.

2.Use the pliers to remove the plastic plugs.

IMPORTANT: Do not throw away the plastic plugs. The plastic plugs must be reinstalled after the blower exhaust scroll has been rotated.

A

E

 

B

 

C

D

 

A. Blower motor

D. Blower bypass

B. Exhaust scroll

E. Plastic plugs (4)

C. Plenum

 

9

Image 9
Contents Cooktop Safety Cooktop Installation InstructionsWhat to do if YOU Smell GAS Installation Requirements Tools and PartsLocation Requirements 36 91.4 cm Cooktop Cabinet DimensionsCold Weather Installations Cutout DimensionsVenting Requirements For Best PerformanceJenn-AirDuct Free Filter Accessory Kit Concrete Slab Installations Exhaust Through WallVenting Methods Option 1 Roof Venting Option 2 Wall VentingCalculating Vent System Length Electrical RequirementsExample vent system Vent Piece Cm RoundType of Gas Gas Supply RequirementsGas Supply Line Gas Pressure RegulatorInstall Cooktop Installation InstructionsGas Supply Pressure Testing Rotate Blower OptionalTo rotate blower motor Make Gas ConnectionComplete Connection Typical flexible connectionElectronic Ignition System Complete InstallationVotre sécurité et celle des autres est très importante Sécurité DE LA Table DE CuissonExigences Dinstallation Exigences demplacementOutillage et pièces Entre le placard et le moteur Dimensions du placard Dimensions de l’ouverture à découperExigences concernant lévacuation Méthodes dévacuation Installations pour régions à climat froidPour obtenir la meilleure performance Air d’appointCalcul de la longueur effective du circuit dévacuation La trousse accessoire de filtration sans conduit Jenn-AirExemple de circuit dévacuation Composant Conduit de diamètre de 15,2 cm Coude à Pi 0,8 mSpécifications de lalimentation en gaz Spécifications électriquesType de gaz Gaz naturelDétendeur de gaz Canalisation de gazCaractéristiques dalimentation du brûleur Test de pressurisation de la canalisation de gazInstallation de la table de cuisson Instructions D’INSTALLATIONRotation du ventilateur Facultative Pour faire pivoter le ventilateurPour faire pivoter le moteur du ventilateur Raccordement au gazAchever le raccordement Raccordement typique par raccord flexibleSi vous avez besoin d’assistance ou de service Achever linstallationSystème dallumage électronique Allumage initial et réglages des flammes de gaz