Bloomfield 8382 owner manual Troubleshooting Suggestions, Symptom Possible Cause Suggested Remedy

Page 12

 

TROUBLESHOOTING SUGGESTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYMPTOM

POSSIBLE CAUSE

SUGGESTED REMEDY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water won’t heat

Brewer unplugged or circuit

Check power supply cord

 

 

 

 

 

breaker tripped

Check / reset circuit breaker

 

 

 

 

 

Thermostat set too low

Set for desired temperature

 

 

 

 

 

 

 

 

 

 

 

 

Hi-Limit thermostat tripped

Allow to cool

 

 

 

 

 

 

Reset hi-limit (8786, 8788)

 

 

 

 

 

Damaged internal component or

Examine wiring & connectors,

 

 

 

 

 

wiring

thermostat and heating element

 

 

 

 

 

 

Repair/replace as needed

 

 

 

 

 

 

 

 

 

 

 

Coffee level low

Water bottle empty

Replace water bottle

 

 

 

 

 

 

 

 

 

 

 

 

Too much coffee grounds

Adjust amount of grounds

 

 

 

 

 

 

 

 

 

 

 

Coffee level too high or low

Timer out of adjustment

Adjust timer

 

 

 

 

 

 

 

 

 

 

 

Brew chamber overflows

Too many filter papers or wrong

Use one (1) genuine Bloomfield

 

 

 

 

 

filter paper

filter per brew

 

 

 

 

 

 

 

 

 

 

 

 

Brew chamber dispense hole

Thoroughly clean brew chamber

 

 

 

 

 

plugged

 

 

 

 

 

 

Too much coffee or too fine a

Adjust coffee amount and grind

 

 

 

 

 

grind

 

 

 

 

 

 

 

 

 

 

 

 

Sprays water from brew head

Spray gasket improperly

Check/reinstall gasket on

 

 

 

 

 

installed

INSIDE of brew head

 

 

 

 

 

 

 

 

 

 

 

 

Spray disk plugged

Plug into electrical power

 

 

 

 

 

 

 

 

 

 

 

No brew

Brewer not plugged in

Clean spray disk

 

 

 

 

 

 

 

 

 

 

 

 

Water bottle empty

Replace water bottle

 

 

 

 

 

 

 

 

 

 

 

 

Bad BREW switch

Replace switch

 

 

 

 

 

 

 

 

 

 

 

 

Damaged internal component or

Examine wiring & connectors,

 

 

 

 

 

wiring

brew switch and solenoid

 

 

 

 

 

 

Repair/replace as needed

 

 

 

 

No flow from hot water faucet

Water bottle empty

Replace water bottle

 

 

 

 

 

 

 

 

 

 

 

Brewer overflows from basin

Damaged water bottle

Install new water bottle

 

 

 

 

 

 

 

 

 

 

 

Poor coffee quality

Water not hot enough

Adjust water temp 195-205ºF

 

 

 

 

 

 

 

 

 

 

 

 

Suggestions for consistently good coffee:

 

 

 

 

 

Keep brewer clean.

 

 

 

 

 

 

Use a quality coffee with a consistent roast.

 

 

 

 

 

Use proper grind and amount of coffee per brew.

 

 

 

 

 

 

 

 

 

10

Image 12
Contents Model Warranty Statement Shipping Damage Claims ProcedureTable of Contents SpecificationsModel Style Volts Watts Amps Power Supply Cord Features and Operating Controls Precautions and General Information Electrical DamageBurn Hazard Agency Approval InformationInstallation Instructions ELECTRICIAN’S Installation InstructionsEquipment Hazard Leveling the UnitSTART-UP OperationPersonal Injury Automatic Operation HOT Water FaucetBrewing Coffee PreparationCleaning Instructions Electric Shock HazardProcedure Clean and Sanitize Basin Pan Electric ShockTroubleshooting Suggestions Symptom Possible Cause Suggested RemedyAccess Panels Temperature AdjustmentServicing Instructions Timer Adjustment Remove Tank LID AssemblyReplace Thermostat Replace Timer Assembly Replace Brew Ready Light or Brew SwitchReplace Heating Element Replace SolenoidProcedure Delime the Water Tank Servicing Instructions Exploded View & Parts List Plumbing ComponentsExploded View & Parts List PART# Description QTY Wiring Diagram Telephone Fax