Bloomfield 8382 owner manual Installation Instructions, Equipment Hazard, Leveling the Unit

Page 6

INSTALLATION INSTRUCTIONS

READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION

IMPORTANT:

To enable the installer to make a quality installation and to minimize installation time, the following suggestions and tests should be done before the actual unit installation is started:

CAUTION: Equipment

Electrical Damage

DO NOT plug in or energize this appliance until all Installation Instructions are read and followed. Damage to the Brewer will occur if these instructions are not followed.

CAUTION: Unstable

Equipment Hazard

It is very important for safety and for proper operation that the brewer is level and stable when standing in its final operating position. Provided adjustable, non-skid legs must be installed at each corner of the unit. Failure to do so will result in movement of the brewer which can cause personal Injury and/ or damage to brewer.

WARNING ELECTRIC SHOCK HAZARD:

Brewer must be plugged into a properly grounded electrical receptacle to prevent possible shock hazard. DO NOT assume a plumbing line will provide such a ground. Electrical shock will cause death or serious injury.

Unpack the unit. Inspect all components for completeness and condition. Ensure that all packing materials have been removed from the unit.

Verify that the Spray Head Gasket (#33) and Spray Disk (#34) are properly installed.

LEVELING THE UNIT

Verify that an adjustable leg is installed at each corner of the brewer.

Set Brewer in its operating location. Level the Brewer. A spirit level should be placed on the top of the unit, at the edge, as a guide when making level adjustments.

Level the unit from left to right and front to back by turning the adjustable feet. Be sure all four feet touch the counter to prevent tipping.

FILL WATER TANK

Check the bottle ring for lint or packing materials. Wipe the interior of the bottle ring with a cloth dampened with clean water.

Brewer is designed to use a 3 gallon or 5 gallon plastic water bottle. Carefully insert a fresh water bottle into the bottle ring.

Wait 30 seconds, or until all bubbling in the bottle stops, then drain water from the hot water faucet until all air is purged from the tank.

ELECTRICIAN’S INSTALLATION INSTRUCTIONS

REFER TO ELECTRICAL SPECIFICATIONS - Page 1 Check the nameplate to determine correct electrical service required for the Brewer to be installed.

IMPORTANT: Before connecting to electricity, make sure a bottle of water is installed on the bottle ring, and all air has been bled from the water tank

Model 8382 is equipped with a cord and plug. It requires a 115 - 125 volt 20 amp circuit (50/60 Hz, 2 wire plus ground, with NEMA 5-15R or 5-20R Receptacle).

IMPORTANT:

Supply power must match nameplate for voltage and phase. Connecting to the wrong voltage will damage the brewer or result in decreased performance. Such damage is not covered by warranty.

IMPORTANT: The ground prong of the plug is part of a system designed to protect you from electrical shock in the event of internal damage. Never cut off the ground prong nor twist a blade to fit an existing receptacle. Contact a licensed electrician to install the proper circuit and receptacle.

4

Image 6
Contents Model Warranty Statement Shipping Damage Claims ProcedureTable of Contents SpecificationsModel Style Volts Watts Amps Power Supply Cord Features and Operating Controls Burn Hazard Precautions and General InformationElectrical Damage Agency Approval InformationEquipment Hazard Installation InstructionsELECTRICIAN’S Installation Instructions Leveling the UnitSTART-UP OperationPersonal Injury Automatic Operation HOT Water FaucetBrewing Coffee PreparationCleaning Instructions Electric Shock HazardProcedure Clean and Sanitize Basin Pan Electric ShockTroubleshooting Suggestions Symptom Possible Cause Suggested RemedyAccess Panels Temperature AdjustmentServicing Instructions Timer Adjustment Remove Tank LID AssemblyReplace Thermostat Replace Heating Element Replace Timer AssemblyReplace Brew Ready Light or Brew Switch Replace SolenoidProcedure Delime the Water Tank Servicing Instructions Exploded View & Parts List Plumbing ComponentsExploded View & Parts List PART# Description QTY Wiring Diagram Telephone Fax