ACCESS PANELS

Top panel is held by four screws at the corners.

Front panel is held by two screws at the bottom and a retaining lip at the top.

Fig. 8 Access Panels

TEMPERATURE ADJUSTMENT

With the “READY TO BREW” light ON, draw a cup of water from the hot water faucet. Check the temperature of the water with a thermometer of known accuracy.

If temperature adjustment is necessary, remove water bottle and top panel.

Adjust thermostat by turning shaft; clockwise increases temperature. 1/8 turn = approximately 10ºF.

Refer to Table 1 below for proper brewing temperature based on altitude.

Upon completion, reinstall top panel.

SERVICING INSTRUCTIONS

CAUTION

Electric Shock

Hazard

Opening access panels on this brew may expose uninsulated electrical components.

Disconnect brewer from electrical power before removing any panel

NOTE:

Optimum brewing temperature range is 195ºF to 205ºF (90ºC to 96ºC).

IMPORTANT:

Amechanical thermostat will maintain temperature within ±10ºF. To prevent boiling water in the brewer, thermostat should be adjusted to a maximum temperature equal to the local boiling temperature minus 10ºF.

210

BOILING POINT OF WATER

TEMP. (ºF)

205

200

195

190

0

 

0

 

 

0

 

 

0

 

 

0

 

0

0

 

0

 

0

 

0

0

0

 

5

 

0

 

5

 

,

 

 

,

 

 

,

 

 

,5

 

 

 

1

 

1

 

2

 

 

2

 

ELEVATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IDEAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BREWING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAXIMUM SAFE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMPERATURE

 

 

0

 

0

 

 

0

 

 

0

 

 

0

 

 

0

 

0

 

 

0

 

SETTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0

 

 

0

 

0

 

0

 

0

 

0

 

 

0

 

 

 

0

 

,5

 

 

0

 

5

 

0

 

5

 

 

,0

 

 

5

 

 

 

 

,

 

 

 

 

,

 

 

,

 

 

,

 

 

,

 

 

6

 

 

,

 

 

 

 

 

3

 

 

3

 

4

 

4

 

 

5

 

 

5

 

 

 

6

 

 

 

 

 

(feet above seal level)

 

 

 

 

 

 

 

 

Table 1 Boiling Temperature by Altitude

11

Image 13
Contents Model Shipping Damage Claims Procedure Warranty StatementSpecifications Table of ContentsModel Style Volts Watts Amps Power Supply Cord Features and Operating Controls Electrical Damage Precautions and General InformationBurn Hazard Agency Approval InformationELECTRICIAN’S Installation Instructions Installation InstructionsEquipment Hazard Leveling the UnitOperation START-UPPersonal Injury HOT Water Faucet Automatic OperationPreparation Brewing CoffeeElectric Shock Hazard Cleaning InstructionsElectric Shock Procedure Clean and Sanitize Basin PanSymptom Possible Cause Suggested Remedy Troubleshooting SuggestionsTemperature Adjustment Access PanelsServicing Instructions Remove Tank LID Assembly Timer AdjustmentReplace Thermostat Replace Brew Ready Light or Brew Switch Replace Timer AssemblyReplace Heating Element Replace SolenoidProcedure Delime the Water Tank Servicing Instructions Plumbing Components Exploded View & Parts ListExploded View & Parts List PART# Description QTY Wiring Diagram Telephone Fax