Bloomfield 8382 owner manual Automatic Operation, HOT Water Faucet

Page 8

OPERATION (continued)

WATER HEATER

Water temperature is sensed by a thermobulb inserted into the water tank. This temperature signal is fed to the thermostat, which controls line power to the heating element.

The setpoint temperature is adjustable at the thermostat.

The element is protected from over- temperature by a hi-limit thermostat.

 

 

 

 

 

 

 

 

 

 

 

HI-LIMIT

 

 

 

 

 

 

 

 

 

 

 

THERMOSTAT

 

 

 

 

 

 

 

 

 

 

 

THERMOBULB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEATER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THERMOSTAT

 

 

 

 

 

 

 

ELEMENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 3 Heat Control Diagram

WATER FLOW

AUTOMATIC OPERATION

Water is supplied to the hot water tank by a bottle inserted in the bottle ring. Water will flow from the bottle into the basin pan until the water level reached the open mouth of the bottle.

Pressing BREW button energizes the solenoid valve, allowing heated water from the hot water tank to flow through the spray head into the brew chamber.

The length of time the solenoid is open is controlled by the timer.

HOT WATER FAUCET

The hot water faucet draws heated water from the water tank.

Fig. 4 Water Flow Diagrams

6

Image 8
Contents Model Warranty Statement Shipping Damage Claims ProcedureModel Style Volts Watts Amps Power Supply Cord Table of ContentsSpecifications Features and Operating Controls Precautions and General Information Electrical DamageBurn Hazard Agency Approval InformationInstallation Instructions ELECTRICIAN’S Installation InstructionsEquipment Hazard Leveling the UnitPersonal Injury START-UPOperation Automatic Operation HOT Water FaucetBrewing Coffee PreparationCleaning Instructions Electric Shock HazardProcedure Clean and Sanitize Basin Pan Electric ShockTroubleshooting Suggestions Symptom Possible Cause Suggested RemedyServicing Instructions Access PanelsTemperature Adjustment Replace Thermostat Timer AdjustmentRemove Tank LID Assembly Replace Timer Assembly Replace Brew Ready Light or Brew SwitchReplace Heating Element Replace SolenoidProcedure Delime the Water Tank Servicing Instructions Exploded View & Parts List Plumbing ComponentsExploded View & Parts List PART# Description QTY Wiring Diagram Telephone Fax