| TROUBLESHOOTING SUGGESTIONS |
|
|
| ||||
|
| SYMPTOM |
| POSSIBLE CAUSE | SUGGESTED REMEDY |
| |||
|
|
|
|
|
|
| |||
|
| Water won’t heat |
| Brewer unplugged or circuit | Check power supply cord |
| |||
|
|
|
| breaker tripped | Check / reset circuit breaker |
| |||
|
|
|
| Thermostat set too low | Set for desired temperature |
| |||
|
|
|
|
|
|
| |||
|
|
|
| Allow to cool |
| ||||
|
|
|
|
|
|
| Reset |
| |
|
|
|
| Damaged internal component | Examine wiring & connectors, |
| |||
|
|
|
| or wiring | thermostat and heating element |
| |||
|
|
|
|
|
|
| Repair/replace as needed |
| |
|
|
|
|
|
|
| |||
|
| Trips |
| No water or too little water | Be sure to add sufficient water |
| |||
|
|
|
| added at | prior to energizing |
| |||
|
|
|
|
|
|
| |||
|
| Coffee level low |
| Not enough water poured in | Increase water amount |
| |||
|
|
|
| Too much coffee grounds | Adjust amount of grounds |
| |||
|
|
|
|
|
|
| |||
|
| Coffee level too high or low |
| Timer out of adjustment | Adjust timer |
| |||
|
| (automatic) |
|
|
|
|
|
|
|
|
| Brew chamber overflows |
| Too many filter papers or wrong | Use one (1) genuine Bloomfield |
| |||
|
|
|
| filter paper | filter per brew |
| |||
|
|
|
| Brew chamber dispense hole | Thoroughly clean brew chamber |
| |||
|
|
|
| plugged |
|
|
| ||
|
|
|
|
|
|
| |||
|
|
|
| Too much coffee or too fine a | Adjust coffee amount and grind |
| |||
|
|
|
| grind |
|
|
| ||
|
|
|
|
|
|
| |||
|
| Sprays water from brew head |
| Spray gasket missing or | Check/reinstall gasket on |
| |||
|
| incorrectly |
| improperly installed | INSIDE of brew head |
| |||
|
|
|
| Spray disk plugged | Clean spray disk |
| |||
|
|
|
|
|
|
| |||
|
| No brew (automatic) |
| Water supply OFF | Turn water supply ON |
| |||
|
|
|
|
|
|
| |||
|
|
|
| Water line strainer plugged | Clean strainer |
| |||
|
|
|
|
|
|
| |||
|
|
|
| Water filter (if used) plugged | Replace filter element |
| |||
|
|
|
|
|
|
| |||
|
|
|
| Damaged BREW switch | Replace switch |
| |||
|
|
|
|
|
|
| |||
|
|
|
| Damaged internal component or | Examine wiring & connectors, |
| |||
|
|
|
| wiring | brew timer and solenoid |
| |||
|
|
|
|
|
|
| Repair/replace as needed |
| |
|
|
|
|
|
|
| |||
|
| No flow from hot water faucet |
| Faucet valve turned OFF | Turn faucet valve ON |
| |||
|
|
|
|
|
|
| |||
|
|
|
| Faucet plugged | Disassemble faucet, clean |
| |||
|
| Poor coffee quality |
| Water not hot enough | Adjust water temp |
| |||
|
|
|
| Also: |
|
|
| ||
|
|
|
| Keep brewer, and decanters clean. |
| ||||
|
|
|
| Install a taste and odor filter in water supply, and replace |
| ||||
|
|
|
| cartridges regularly. |
|
|
| ||
|
|
|
| Use a quality coffee with a consistent roast. Use proper grind and |
| ||||
|
|
|
| amount of coffee per brew. |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 10 |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
605 70988 Owners Manual Integrity 5W Decanter Brewer