INSTALLATION

READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION

IMPORTANT:

To enable the installer to make a quality installation and to minimize installation time, the following suggestions and tests should be done before the actual unit installation is started:

REFER TO EXPLODED VIEWS FOR COMPONENT NAMES/ NUMBERS

Unpack the unit. Inspect all components for completeness and condition. Ensure that all packing materials have been removed from the unit.

Verify that the Spray Head Gasket and Spray Disk are properly installed.

CAUTION:

ELECTRICAL

DAMAGE

DO NOT plug in or energize this appliance until all Installation Instructions are read and followed. Damage to the Brewer will occur if these instructions are not followed.

CAUTION:

UNSTABLE

EQUIPMENT HAZARD

DO NOT operate brewer unless factory supplied adjustable legs are installed and properly adjusted.

It is very important for safety and for proper operation that the brewer is level and stable when standing in its final operating position. Provided adjustable legs must be installed at each corner of the unit. Failure to do so will result in movement of the brewer which can cause personal Injury and/or damage to brewer.

NOTE: Water supply inlet line must meet certain minimum criteria to insure successful operation of the brewer. Bloomfield recommends 1/4" copper tubing for installation of less than 12 feet and 3/8" for more than 12 feet from a 1/2" water supply line.

LEVELING THE UNIT

Verify that provided adjustable legs are installed at each corner of the brewer.

Set Brewer in its operating location. Level the Brewer. A spirit level should be placed on the top of the unit, at the edge, as a guide when making level adjustments.

Level the unit from left to right and front to back by turning the adjustable feet. Be sure all four feet touch the counter to prevent tipping.

PLUMBER’S INSTALLATION INSTRUCTIONS

Brewer should be connected to a POTABLE WATER, COLD WATER line. Flush water line before connecting to Brewer.

DO NOT use a saddle valve with a self-piercing tap for the water line connection. Such a tap can become restricted by waterline debris. For systems that must use a saddle tap, shut off the main water supply and drill a 3/16” (minimum) tap for the saddle connection, in order to insure an ample water supply. Remember to flush the line prior to installing the saddle.

The brewer must be installed on a water line with average pressure between 20 PSI and 90 PSI. If your water pressure exceeds 90 PSI at anytime, a pressure regulator must be installed in the water supply line to limit the pressure to not more than 90 PSI in order to avoid damage to lines and solenoid.

605 70988 Owners Manual Integrity 5W Decanter Brewer

4

Image 6
Contents 605 Warranty Statement Table of Contents SpecificationsApplicability Features and Operating Controls Electrical Damage Precautions and General InformationAgency Listing Information Burn HazardUnstable Equipment Hazard InstallationPLUMBER’S Installation Instructions Leveling the UnitELECTRICIAN’S Installation Instructions Shock HazardOperation START-UPPOUR-OVER Feature Automatic OperationHOT Water Faucet Brewing Coffee PreparationPOUR-OVER Operation Procedure Clean Coffee Brewer Cleaning InstructionsTroubleshooting Suggestions Symptom Possible Cause Suggested RemedyAccess Panels Servicing InstructionsTemperature Adjustment Servicing InstructionsReplace Thermostat Timer AdjustmentRemove Tank LID Assembly Replace Heating ElementClean Solenoid Screen Replace SolenoidReplace Timer Assembly Replace HOT Water Faucet CoilRepair HOT Water Faucet Procedure Delime the Water Tank Chemical Burn HazardServicing Instructions Exploded View & Parts List Cabinet AssemblyExploded View & Parts List Electrical ComponentsHOT Water Tank Assembly Plumbing Components Service Kits Faucet Repair KitsWiring Diagram Telephone Fax