SERVICING INSTRUCTIONS (continued)
Fig. 11 Remove Faucet Supply from Solenoid
REPLACE SOLENOID
Symptom: Automatic brewer will not flow water; or, automatic brewer drips continuously from brew head.
Unplug power cord or turn circuit breaker OFF. Turn OFF and disconnect water supply from brewer inlet fitting.
Unscrew water inlet fitting from solenoid.
Remove two screws holding access door in place. Remove two screws holding solenoid to door.
Disconnect wiring from solenoid.
Slide the 7/16" end of the wrench between the valve body and the white ring on the extreme end of the metal hose fitting.
Pressure on the white ring toward the metal ferrule releases the clinch ring, allowing the hose to be easily slid off of the solenoid bypass outlet.
Transfer solenoid bracket to new solenoid.
Reinstall hose by pressing end of hose onto bypass outlet until it is fully seated.
Reassemble in reverse order.
CLEAN SOLENOID SCREEN
Symptom: Automatic brewer will not flow water.
Unplug power cord or turn circuit breaker OFF. Turn OFF and disconnect water supply from brewer inlet fitting.
Unscrew water inlet fitting from solenoid.
Using
Reinsert screen in solenoid. Be careful to maintain correct orientation. (The OPEN END of the screen goes in FIRST.)
Reassemble in reverse order.
605 70988 Owners Manual Integrity 5W Decanter Brewer
Fig. 12 Clean Strainer Screen
14