SPECIAL COMPONENTS TEST AND ADJUSTMENTS

1) WATER INLET VALVE (SOLENOID) TEST (Located inside bottom cabin) Turn power off from touchpad. If the water level rises inside the tank, and shoots out of the overflow, the Water Inlet Valve is leaking. Disconnect wires from the Water Inlet Valve coil and connect a 2 wire line cord to the terminals. Plug it into a 115V outlet. If water flows in and stops when you pull it out, the Valve is working fine. Repeat this test a few times. The problem may be in the Probe. If the water does not flow in when the cord is plugged into an electrical outlet, the Solenoid coil may be damaged, opened or the valve may have an obstruction preventing the water from flowing in. Clean or replace it.

A Check Valve is installed to prevent backflow.

To check proper function of Check Valve, disconnect water line from the Check

Valve, check for dripping from the disconnected end of the Check Valve.

If it leaks replace it.

Water inlet Valve max. flow rate is 1.3 gal/min.

2) WATER LEVEL PROBE TEST (Located on tank top, inside top cabin) If there is a lack of water, you will get an error message on the LCD window. Check the probe as follows:

Turn on the power from touchpad and water supply. Check inside the tank to make sure the water is not touching the Probe. Pull the wire and terminal out of the Probe rod. If water starts flowing into the tank, the Probe may be grounded, due to excessive liming. Check with Ohm meter. Clean or replace.

3) POWER SAFETY RELAY TEST (Located inside top cabin)

Turn power switch on from touchpad. Measure Voltage across Input to Coil, between terminals1& 2. Should read approx. 9V to 10V D.C.

Measure Voltage across Input, between terminals “COM” to Ground. Should read 120V. Measure Voltage across Output, between terminals “NO” to Ground. Should read 120V.

4)HEATER SAFETY RELAY TEST (240V UNITS ONLY) (Located inside top cabin) Make sure power switch in back of unit is on (toggle up).

Turn power switch on (energize) from touchpad. Measure Input Voltage across coil,

between terminals 0 & 1. Should read 120V.

Measure Output Voltage across Heater Element. Should read 220 V. If there is no Voltage across the Heating Element, measure Output Voltage between terminals 4 & 8.

Turn power switch off from touchpad. The Voltage should be a constant 220V even when not energized.

Turn power switch on) from touchpad. Measure Voltage across terminals 2 & 6. Should read 220V. If 120V was applied to relay coil and it does not energize, replace relay.

17

Image 17
Contents Manual ModelsMechanical Specifications Specifications Electrical SpecificationsSTART-UP Procedure Plug the Power Cord Into a Proper ReceptaclePage Installation and Operating Instructions Programming Instructions Powerwarmercancel Lastbrew ButtonbuttonsoperationbuttonModes of Operation Overview To Scroll Thru Programming FunctionsModes of Operation Descriptions Brew Fill Constant Calibration State Brewing StateWarmers Real-Time-ClockService Mode Lockout Temperature Water TemperatureSleep Timer ON/OFF Warmer PowerAudible Alarm ON/OFF Warmer Timer ON/OFFWeekday Timer ON/OFF Weekend Timer ON/OFFAdjust Minutes DAY HH##SS Adjust Seconds DAY HHMM##Adjust Hours DAY ##MMSS Adjust DAYError Mode 2003G-IT Front Open View 23 24 25 26 27 28 TOP Cabin Open ViewQTY Description HI-LIMIT, Surface Mount 220 ˚FProblem Probable Cause Remedy Troubleshooting GuidePower Safety Relay Test Located inside top cabin Special Components Test and AdjustmentsTo Adjust Water Flow Rate To prepare a sanitizing solutionCecilware Corporation