INFUSION TIME - OPTIONAL | INFUSION TIME |
| ## SECONDS |
Description – The Infusion Time is the amount of time that the system will dispense (infuse) hot water into the grinds during the
SOAK TIME – OPTIONAL | SOAK TIME |
| ## SECONDS |
Description – The Soak Time is the amount of time that the system will wait between the end of the hot water infusion period and the beginning of brewing.
PULSE BREW - OPTIONAL | PULSE BREW |
| ON/OFF |
Description – The Pulse Brew feature gives the user the ability to brew by
PULSE ON TIME | PULSE ON TIME |
| ## SECONDS |
Description – The Pulse ON Time is the amount of time that the system will continuously dispense hot water during a Brew Cycle.
PULSE OFF TIME | PULSE OFF TIME |
| ## SECONDS |
Description – The Pulse OFF Time is the amount of time that the system will wait between hot water dispenses during a Brew Cycle.
DRIP TIME | DRIP TIME |
### SECONDS
Description – The Drip Time is the amount of time that the system will wait after the completion of the hot water dispense before signaling the end of the Brew Cycle. This allows time for any water remaining in the funnel to drain out.
WATER TEMPERATURE | WATER TEMP |
| ### °F |
Description – The Water Temperature is the required (set point) temperature of the water in the reservoir tank.
TEMPERATURE SENSOR CALIBRATION | TEMP SENSOR CAL |
| ARE YOU SURE ? |
Description – The Temperature Sensor Calibration allows the user to offset (calibrate) the displayed water temperature to a reference thermometer.
Instructions – Use the [Arrow] Keys to adjust (calibrate) the displayed | TEMP SENSOR CAL |
temperature to match the reference thermometer. Depress one of the | ### °F |
[Hidden] Keys when the calibration is complete. |
|
LOCKOUT TEMPERATURE | LOCKOUT TEMP |
| ### °F |
Description – The Lockout Temperature is the minimum brewing temperature. The system will not allow a Brew Cycle to begin unless the water is above the Lockout Temperature.
SLEEP TIMER | SLEEP TIMER |
| ON/OFF |
Description – The Sleep Timer feature automatically reduces the water temperature to three degrees above the Lockout Temperature if the machine has not started a Brew Cycle within two hours.
WARMER POWER | WARMER POWER |
| ### % |
Description – The Warmer Power feature allows the user to reduce the actual heating power of the warmers. The percentage displayed is percentage of maximum power.
9