Cecilware C-2003G-IT Infusion Time Optional ## Seconds, Soak Time Optional ## Seconds, Drip Time

Page 9

INFUSION TIME - OPTIONAL

INFUSION TIME

 

## SECONDS

Description – The Infusion Time is the amount of time that the system will dispense (infuse) hot water into the grinds during the Pre-Infusion process.

SOAK TIME – OPTIONAL

SOAK TIME

 

## SECONDS

Description – The Soak Time is the amount of time that the system will wait between the end of the hot water infusion period and the beginning of brewing.

PULSE BREW - OPTIONAL

PULSE BREW

 

ON/OFF

Description – The Pulse Brew feature gives the user the ability to brew by non-continuously dispensing (pulsing) hot water.

PULSE ON TIME -OPTIONAL

PULSE ON TIME

 

## SECONDS

Description – The Pulse ON Time is the amount of time that the system will continuously dispense hot water during a Brew Cycle.

PULSE OFF TIME -OPTIONAL

PULSE OFF TIME

 

## SECONDS

Description – The Pulse OFF Time is the amount of time that the system will wait between hot water dispenses during a Brew Cycle.

DRIP TIME

DRIP TIME

### SECONDS

Description – The Drip Time is the amount of time that the system will wait after the completion of the hot water dispense before signaling the end of the Brew Cycle. This allows time for any water remaining in the funnel to drain out.

WATER TEMPERATURE

WATER TEMP

 

### °F

Description – The Water Temperature is the required (set point) temperature of the water in the reservoir tank.

TEMPERATURE SENSOR CALIBRATION

TEMP SENSOR CAL

 

ARE YOU SURE ?

Description – The Temperature Sensor Calibration allows the user to offset (calibrate) the displayed water temperature to a reference thermometer.

Instructions – Use the [Arrow] Keys to adjust (calibrate) the displayed

TEMP SENSOR CAL

temperature to match the reference thermometer. Depress one of the

### °F

[Hidden] Keys when the calibration is complete.

 

LOCKOUT TEMPERATURE

LOCKOUT TEMP

 

### °F

Description – The Lockout Temperature is the minimum brewing temperature. The system will not allow a Brew Cycle to begin unless the water is above the Lockout Temperature.

SLEEP TIMER

SLEEP TIMER

 

ON/OFF

Description – The Sleep Timer feature automatically reduces the water temperature to three degrees above the Lockout Temperature if the machine has not started a Brew Cycle within two hours.

WARMER POWER

WARMER POWER

 

### %

Description – The Warmer Power feature allows the user to reduce the actual heating power of the warmers. The percentage displayed is percentage of maximum power.

9

Image 9
Contents Manual ModelsMechanical Specifications Specifications Electrical SpecificationsSTART-UP Procedure Plug the Power Cord Into a Proper ReceptaclePage Installation and Operating Instructions Programming Instructions Powerwarmercancel Lastbrew ButtonbuttonsoperationbuttonModes of Operation Overview To Scroll Thru Programming FunctionsModes of Operation Descriptions Brew Fill Constant Calibration State Brewing StateWarmers Real-Time-ClockService Mode Lockout Temperature Water TemperatureSleep Timer ON/OFF Warmer PowerAudible Alarm ON/OFF Warmer Timer ON/OFFWeekday Timer ON/OFF Weekend Timer ON/OFFAdjust Minutes DAY HH##SS Adjust Seconds DAY HHMM##Adjust Hours DAY ##MMSS Adjust DAYError Mode 2003G-IT Front Open View 23 24 25 26 27 28 TOP Cabin Open ViewQTY Description HI-LIMIT, Surface Mount 220 ˚FProblem Probable Cause Remedy Troubleshooting GuidePower Safety Relay Test Located inside top cabin Special Components Test and AdjustmentsTo Adjust Water Flow Rate To prepare a sanitizing solutionCecilware Corporation