Cecilware C-2003LG-IT, C-2003G-IT Programming Instructions, Modes of Operation Overview, Led

Page 5

PROGRAMMING INSTRUCTIONS

TO ACCESS PROGRAMMING: Press

Simultaneously Both Buttons

TO SCROLL THRU PROGRAMMING FUNCTIONS:

Press One Button

TO CHANGE OR RESET

LED

PARAMETER VALUES

 

LIGHTS

 

D:\1-Milt\Labels & Logos\Techno copy.tif

LCD WINDOW…………

CAUTION

 

HOT WATER

NG34A-E

POWERWARMERCANCEL LASTBREW

BUTTONBUTTONSOPERATIONBUTTON

The following is a Functional Description of the Single Station Brewer:

Modes of Operation - Overview

Initialization Mode – This mode is only active during the first few seconds after a “power-on” or system reset. The main function of this mode is to perform some special self-testing functions and configure the system using the previously saved operating parameters.

Normal Mode – This mode becomes active immediately after Initializing Mode has completed its tasks. The main functions of this mode are to monitor and report system status and control brewing.

Service Mode – This mode becomes active when the hidden keys under the Cecilware Logo (located on the upper-left-hand side of the keypad) and the first letter of the Model Name (located on the upper- right-hand side of the keypad) are simultaneously depressed for more than two seconds while in Normal Mode. The main function of this mode is to allow access (for qualified personnel) to all system parameters that can be modified.

Error Mode – This mode becomes active when the system detects a fatal error. The main function of this mode is to disable the unit and report the error to the operator.

5

Image 5
Contents Manual ModelsMechanical Specifications Specifications Electrical SpecificationsSTART-UP Procedure Plug the Power Cord Into a Proper ReceptaclePage Installation and Operating Instructions Programming Instructions Powerwarmercancel Lastbrew ButtonbuttonsoperationbuttonModes of Operation Overview To Scroll Thru Programming FunctionsModes of Operation Descriptions Brew Fill Constant Calibration State Brewing StateWarmers Real-Time-ClockService Mode Lockout Temperature Water TemperatureSleep Timer ON/OFF Warmer PowerAudible Alarm ON/OFF Warmer Timer ON/OFFWeekday Timer ON/OFF Weekend Timer ON/OFFAdjust Minutes DAY HH##SS Adjust Seconds DAY HHMM##Adjust Hours DAY ##MMSS Adjust DAYError Mode 2003G-IT Front Open View 23 24 25 26 27 28 TOP Cabin Open ViewQTY Description HI-LIMIT, Surface Mount 220 ˚FProblem Probable Cause Remedy Troubleshooting GuidePower Safety Relay Test Located inside top cabin Special Components Test and AdjustmentsTo Adjust Water Flow Rate To prepare a sanitizing solutionCecilware Corporation