Cecilware C-2003G-IT, C-2003RG-IT, C-2003LG-IT specifications Modes of Operation Descriptions

Page 6

MODES OF OPERATION – DESCRIPTIONS

Initialization Mode:

The following screen signifies the presence of this mode:

CECILWARE

&&&&& REV #.#

Description – This mode is active only during the first few seconds after “power-on”. The purpose of the Initialization Screen is to identify the System Software Title (depicted by “&&&&&”) and Revision Number (depicted by “#.#”).

Normal Mode:

The following screen signifies the presence of Normal Mode:

SSSSSSDDD K SSSSSS HH:MMP

Description – Normal Mode is active immediately after Initialization Mode. The left half of the screen displays the present System State (depicted by “S”). Refer to the subsequent State Descriptions in this section for more information on System States. The right half of the screen displays the present day of the week (depicted by “D”), the present time (depicted by “HH”:”MMP”), and the current KeyLock Status (depicted by “K”). The day of the week is identified using familiar three letter abbreviations. The time is identified using hours and minutes along with a “AM/PM” indicator. If KeyLock is enabled the” KL” symbol will be present. Enabling KeyLock will prevent unauthorized users from operating the unit. Refer to the Service Mode Descriptions for more information on the KeyLock function.

Filling State

FILLING DDD K TANK HH:MMP

Description – This screen is displayed during the initial filling of the water tank (first fill). Once the water in the reservoir tank has reached the appropriate fill level this screen is retired.

Heating State:

HEATING DDD K TTTF HH:MMP

Description – This screen is displayed when the present water temperature is below the Lockout Temperature Set Point. The actual water temperature is displayed in the lower left-hand portion of the screen (depicted by “TTTF”). If the Brew Key is depressed while in the Heating State the system will advance to the Waiting State. If the Brew Key is depressed for more that three seconds the Waiting State is bypassed and the system will advance to the Brewing State.

Waiting State

WAITING DDD K TTTF HH:MMP

Description – This screen is displayed when the operator presses the Brew Key while the system is in the Heating State. The actual water temperature is displayed in the lower left-hand portion of the screen (depicted by “TTTF”). The Brew Key LED will blink in this state. Once the water temperature reaches the Lockout Temperature Set Point the system will automatically advance to the Brewing State.

Pressing the Brew Key or the Cancel Key while in the Waiting State will cause the system to revert back to the Heating State.

Ready (to Brew) State

READY

DDD K

TO BREW

HH:MMP

Description – This screen is displayed when the system is ready to begin a Brew Cycle. Pressing the Brew Key while in the Ready State will advance the system to the Brewing State (i.e. begin a Brew Cycle).

6

Image 6
Contents Models ManualSTART-UP Procedure Specifications Electrical SpecificationsMechanical Specifications Plug the Power Cord Into a Proper ReceptaclePage Installation and Operating Instructions Modes of Operation Overview Powerwarmercancel Lastbrew ButtonbuttonsoperationbuttonProgramming Instructions To Scroll Thru Programming FunctionsModes of Operation Descriptions Warmers Brewing StateBrew Fill Constant Calibration State Real-Time-ClockService Mode Sleep Timer ON/OFF Water TemperatureLockout Temperature Warmer PowerWeekday Timer ON/OFF Warmer Timer ON/OFFAudible Alarm ON/OFF Weekend Timer ON/OFFAdjust Hours DAY ##MMSS Adjust Seconds DAY HHMM##Adjust Minutes DAY HH##SS Adjust DAYError Mode 2003G-IT Front Open View TOP Cabin Open View 23 24 25 26 27 28HI-LIMIT, Surface Mount 220 ˚F QTY DescriptionTroubleshooting Guide Problem Probable Cause RemedySpecial Components Test and Adjustments Power Safety Relay Test Located inside top cabinTo prepare a sanitizing solution To Adjust Water Flow RateCecilware Corporation