Cecilware C-2003G-IT, C-2003RG-IT To prepare a sanitizing solution, To Adjust Water Flow Rate

Page 18

5) CHECK DISPENSE VALVES FOR LIME BUILD-UP (Located inside top cabin) Drain The Water Tank To Just Below The Level Of The Dispense Valves.

Remove The Valves And Clean. You Can Take These Valves Apart By Hand As Shown. Replace The Assembly As Needed.

Replace The Valve Into The Tank And Refill tank.

The SINGLE DISPENSE VALVE is factory adjusted to dispense 0.35 oz./sec. of water during the brew cycle (spray duration).

TO ADJUST WATER FLOW RATE:

Locate adjustment screw on valve (as show here).

Using an Allen Key or a flat screwdriver, rotate ¼ turn at a time,

Clockwise (CW) to decrease water flow rate or

Counter-Clockwise (CCW) to increase water flow rate.

Check water flow output after each ¼ turn.

CLEANING AND SANITIZING

SANITIZING:

All food dispensing units should be sanitized periodically. All parts to be sanitized must be cleaned first.

To prepare a sanitizing solution:

ADD 2 TSP. OF LIQUID CLOROX BLEACH (5.25% CONCENTRATION) TO 1 GALLON OF WATER AT ROOM TEMPERATURE (70°- 90°F). Note: Always start with a unopened bottle of Clorox Bleach since the solution from an opened bottle has a short life span.

Soak all parts for a minimum of 3 min. in the sanitizing solution.

Let all sanitized parts drain and dry naturally. DO NOT WIPE THEM DRY.

Before using the sanitized unit (or parts) with food stuffs, rinse all parts thoroughly with water.

Water pipe connecting and fixtures directly connected to a potable water supply shall be sized, installed, and maintained in accordance with Federal, Sate, and Local codes (section 7).

CLEANING:

1.Empty contents from brew funnel, wash and let dry (use a mild dishwasher detergent).

2.To wash machine surfaces, first turn power switch OFF, wipe down machine surfaces, then turn power switch ON.

18

Image 18
Contents Models ManualSTART-UP Procedure Specifications Electrical SpecificationsMechanical Specifications Plug the Power Cord Into a Proper ReceptaclePage Installation and Operating Instructions Modes of Operation Overview Powerwarmercancel Lastbrew ButtonbuttonsoperationbuttonProgramming Instructions To Scroll Thru Programming FunctionsModes of Operation Descriptions Warmers Brewing StateBrew Fill Constant Calibration State Real-Time-ClockService Mode Sleep Timer ON/OFF Water TemperatureLockout Temperature Warmer PowerWeekday Timer ON/OFF Warmer Timer ON/OFFAudible Alarm ON/OFF Weekend Timer ON/OFFAdjust Hours DAY ##MMSS Adjust Seconds DAY HHMM##Adjust Minutes DAY HH##SS Adjust DAYError Mode 2003G-IT Front Open View TOP Cabin Open View 23 24 25 26 27 28HI-LIMIT, Surface Mount 220 ˚F QTY DescriptionTroubleshooting Guide Problem Probable Cause RemedySpecial Components Test and Adjustments Power Safety Relay Test Located inside top cabinTo prepare a sanitizing solution To Adjust Water Flow RateCecilware Corporation