AEG 84602 G, 85600 G, 856001 G manual Instructions for the Installer, Engineer technical data

Page 12

Instructions for the Installer

Engineer technical data

OVERALL DIMENSIONS

Width:

580 mm.

 

Depth:

510 mm.

 

Height:

88 mm.

 

Weight:

8 Kg.

CUT OUT DIMENSIONS

Width:

550 mm.

 

Depth:

470 mm.

 

Thickness:

30 mm.

SUPPLY CONNECTIONS

Gas:

 

 

RC 1/2 inch (1/2 inch male) Rear right hand corner

 

Electric:

 

 

230-240V 50Hz supply, 3 core flexible cable with

 

non rewireable plug fitted with a 3 amp cartridge fuse.

IGNITION HT SPARK

Spark Generator

 

Ispra Control's BF 50046 - 230-240V 0.6 YA T120

HEAT INPUT

Spark Gap : Fixed

 

 

Rear Left Burner

1.9 kW (6483 BTU/HR)

(semi rapid)

 

 

Front Left Burner

2.9 kW Natural Gas (9895 BTU/HR)

(rapid)

2.7 kW L.P.G. (9212 BTU/HR)

Rear Right Burner

1.9 kW (6483 BTU/HR)

(semi rapid)

 

 

Front Right Burner

1.0 kW (3412 BTU/HR)

(auxiliary)

 

 

APPLIANCE CLASS

3

 

APPLIANCE CATEGORY

II2H3+

 

GAS SUPPLY

Natural gas G20 / 20mbar

12

Image 12
Contents 85600 G 856001 G Installation Child SafetyDuring Use Service Environmental InformationContents Guide to Use the instructions Installation Description of the HobOperation HOB BurnersMaintenance and Cleaning Hob TopPan Supports BurnersSymptom Solution Something Not Working?Service and Spare Parts 0870 5 929Guarantee Conditions European GuaranteeInstructions for the Installer Engineer technical dataBurner Important safety requirements LocationInstallation Gas Connection Cut Out Size BuildingBuilding over a cupboard or drawer Building over a kitchen unit with door Fitting the hob to the worktop Electrical connections This HOB Must be EarthedWiring diagram Permanent ConnectionFault Finding Preliminary Electrical Systems CheckEarth Continuity Check Ignition System / Gas Ignition Check gas supply at burnerPressure Testing CommissioningConversion from Natural Gas to LPG Method