AEG 85600 G, 84602 G, 856001 G manual Burner

Page 13

 

 

BURNER

 

RAPID

SEMI-RAPID

AUXILIARY

 

 

TYPE OF GAS

 

 

(large)

(medium)

(small)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POSITION

 

MAX

MIN

MAX

MIN

MAX

MIN

 

 

 

NOMINAL THERMAL

 

 

 

 

 

 

 

 

 

 

NATURAL GAS

POWER

kW

2.9

0.65

1.9

 

0.45

1.0

0.33

 

 

NOMINAL FLOW

 

 

 

 

 

 

 

 

 

 

20 mbar

 

 

 

 

 

 

 

 

 

 

VALUE =

RATE

m3/h

0.276

0.062

0.181

0.043

0.095

0.031

 

 

37.78 MJ/m3

NOZZLE REFERENCE

 

119

Adjust.

96

 

Adjust.

70

Adjust.

 

 

Ws - 50.7 MJ/ m3

 

 

 

 

 

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

NOMINAL THERMAL

 

 

 

 

 

 

 

 

 

 

LPG GAS

POWER

kW

2.7

0.65

1.9

 

0.45

1.0

0.33

 

 

28-30/37 mbar

NOMINAL FLOW

 

 

 

 

 

 

 

 

 

 

VALUE =

 

 

 

 

 

 

 

 

 

 

RATE

g/h

195

46.8

137

32.4

72

23.8

 

 

49.92 MJ/Kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOZZLE REFERENCE

 

86

40

71

 

32

50

28

 

 

 

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner

Dia. Tap By-pass

 

Tap colour

 

 

 

 

 

 

 

 

1/100 mm

 

 

 

 

 

 

 

 

 

Auxiliary

28

 

Red/Red

 

 

 

 

 

 

 

Semi-rapid

32

 

Blue/Blue

 

 

 

 

 

 

 

Rapid

40

 

Black/Black

 

 

 

 

 

 

 

Aeration adjustment none

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

Image 13
Contents 85600 G 856001 G Child Safety InstallationDuring Use Environmental Information ServiceContents Guide to Use the instructions Description of the Hob InstallationHOB Burners OperationHob Top Maintenance and CleaningPan Supports BurnersSomething Not Working? Symptom Solution0870 5 929 Service and Spare PartsEuropean Guarantee Guarantee ConditionsEngineer technical data Instructions for the InstallerBurner Location Important safety requirementsInstallation Gas Connection Building Cut Out SizeBuilding over a cupboard or drawer Building over a kitchen unit with door Fitting the hob to the worktop This HOB Must be Earthed Electrical connectionsPermanent Connection Wiring diagramPreliminary Electrical Systems Check Fault FindingEarth Continuity Check Check gas supply at burner Ignition System / Gas IgnitionCommissioning Pressure TestingMethod Conversion from Natural Gas to LPG