AEG 85600 G, 84602 G, 856001 G manual Fault Finding, Preliminary Electrical Systems Check

Page 22

Fault Finding

 

 

Brown

Blue

Green

 

 

 

Preliminary Electrical Systems Check

 

Yellow

 

 

START

 

 

 

Blue

 

Isolate appliance

 

 

 

and carry out:

 

 

Brown

Green

A: Earth Continuity

 

 

 

Yellow

check.

 

 

 

 

 

 

NO

YES

Carry out:

 

Carry out:

 

 

 

D: Resistance to

 

 

 

C: Polarity check.

 

 

 

 

 

Earth check.

 

 

 

 

 

 

 

 

Has inlet fuse blown?

 

 

Electricity supply

 

NO

 

YES

 

should now be

 

 

 

 

satisfactory.

 

 

 

 

PLUG (with cover removed)

SOCKET

 

Inlet wiring

 

Earth Wire

 

 

(face view)

faulty.

 

 

 

 

 

 

Green/Yellow

(

)

 

 

Rectify any

 

E (

)

 

 

fault.

 

 

 

 

 

 

 

 

 

 

 

 

Neutral Wire

 

FUSE

 

 

 

 

Blue

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

L

 

Isolate appliance and

 

 

 

 

 

carry out:

 

 

 

 

 

 

B: Insulation check.

 

 

 

 

 

Rectify any fault

 

 

 

 

 

including replacing

 

 

 

 

 

fuses as necessary.

 

 

 

 

22

 

 

 

 

 

 

Image 22
Contents 85600 G 856001 G Child Safety InstallationDuring Use Service Environmental InformationContents Guide to Use the instructions Installation Description of the HobOperation HOB BurnersPan Supports Maintenance and CleaningHob Top BurnersSymptom Solution Something Not Working?Service and Spare Parts 0870 5 929Guarantee Conditions European GuaranteeInstructions for the Installer Engineer technical dataBurner Important safety requirements LocationInstallation Gas Connection Building Cut Out SizeBuilding over a cupboard or drawer Building over a kitchen unit with door Fitting the hob to the worktop Electrical connections This HOB Must be EarthedWiring diagram Permanent ConnectionFault Finding Preliminary Electrical Systems CheckEarth Continuity Check Ignition System / Gas Ignition Check gas supply at burnerPressure Testing CommissioningConversion from Natural Gas to LPG Method