AEG 856001 G, 84602 G, 85600 G manual Conversion from Natural Gas to LPG, Method

Page 26

Conversion from Natural Gas to LPG

It is important to note that this model is designed for use with natural gas but can be converted for use with butane or propane gas providing the correct injectors are fitted. The gas rate is adjusted to suit.

Method

1) Ensure that the gas taps are in the 'OFF' position

2)Isolate the hob from the electricity supply

3)Remove all pan supports, burner caps, rings, crowns and control knobs.

4)With the aid of a 7mm box spanner the burner injectors can then be unscrewed and replaced by the appropriate LPG injectors.

TO ADJUST THE GAS RATE

With the aid of a thin bladed screwdriver completely tighten down the by pass adjustment screw, which is located down the centre of the gas tap control shaft. Upon completion stick the replacement rating plate on the under side of the hob.

IMPORTANT

The replacement/conversion of the gas hob should only be undertaken by a competent person

26

Image 26
Contents 85600 G 856001 G During Use InstallationChild Safety Service Environmental InformationContents Guide to Use the instructions Installation Description of the HobOperation HOB BurnersPan Supports Maintenance and CleaningHob Top BurnersSymptom Solution Something Not Working?Service and Spare Parts 0870 5 929Guarantee Conditions European GuaranteeInstructions for the Installer Engineer technical dataBurner Important safety requirements LocationInstallation Gas Connection Building over a cupboard or drawer Cut Out SizeBuilding Building over a kitchen unit with door Fitting the hob to the worktop Electrical connections This HOB Must be EarthedWiring diagram Permanent ConnectionFault Finding Preliminary Electrical Systems CheckEarth Continuity Check Ignition System / Gas Ignition Check gas supply at burnerPressure Testing CommissioningConversion from Natural Gas to LPG Method