Antunes, AJ VCT-25, VCT-20, VCT-50 owner manual Troubleshooting

Page 14

VERTICAL CONTACT TOASTER

TROUBLESHOOTING (continued)

Problem

Possible Cause

Corrective Action

Platen is hot and conveyor belts

Toaster is installed incor-

Perform installation and operating proce-

do not move.

rectly.

dures (pages 7-8).

 

Wiring problems.

Check all electrical connections for burns,

 

 

discoloration or arcing. Replace all connec-

 

 

tions or components with damaged terminals.

 

 

Replace all damaged wiring with the same

 

 

(or higher) rated wire.

 

Drive motor inoperable or

To check drive motor:

 

incorrect conveyor drive

1.Measure resistance of motor coil. Replace

 

motor.

 

 

motor if coil measures either open circuit

 

 

or zero resistance.

 

 

2.Mark the drive motor sprocket and count

 

 

the turns per minute. Correct drive motor

 

 

speed is nine (9) turns per minute for VCT-

 

 

20; three (3) turns per minute for VCT-25;

 

 

one (1) turn per minute for VCT-50.

 

Broken drive chain or loose

Check drive chain for kinks, broken or bent

 

sprocket.

links or other damage. Check motor sprocket

 

 

and drive sprockets (on drive shaft); tighten

 

 

setscrew on flat of shaft if required. Check

 

 

for damaged/worn sprockets and replace as

 

 

required.

 

Heat shield. not installed.

Install heat shield.

 

Conveyor belts installed

Install conveyor belt to match diagram in Fig.

 

incorrectly.

8 (page 11). Be sure that ends of the hooks

 

 

are facing down.

 

Conveyor interlock switch

Install heat shield. correctly.

 

not depressed.

 

 

Spring tensioner assy. or

Replace spring tensioner assy(s). (29, page

 

tensioner bent or missing.

22) or tensioners (4, page 24) if damaged or

 

 

loose.

 

 

Replace slide rails (40, page 24) if worn or

 

 

missing.

 

Conveyor belt too loose

Remove conveyor belt (page 11). Lay belt

 

or missing links (41 links

flat and count links. Replace entire belt if

 

required when new). When

links are damaged. If conveyor belt has too

 

new, conveyor has 37 large

much play, it will jam. Adjust belt length as

 

links and 4 small links.

described under Servicing Conveyor Belts

 

 

(page 11).

14

P/N 1010729 Rev. C 05/04

Image 14
Contents Vertical Contact Toaster Table of Contents Owner InformationService/Technical Assistance Owner InformationImportant Safety Information DeathElectrical Cord & Plug Configurations Important Safety InformationSpecifications Electrical RatingsSpecifications DimensionsAssembling the Unit InstallationUnpacking Installation Equipment SetupOperation Operating InstructionsCleaning the Release Sheet MaintenanceMaintenance Schedule Conveyor Belts-Removing, Servicing & ReplacingMaintenance Replacing Spring TensionersReplacing Conveyor Motor and Fan Blade Motor Mounting Screw 310P154 Fan BladeTroubleshooting Problem Possible Cause Corrective ActionTroubleshooting Vertical Contact Toaster Vertical Contact Toaster Vertical Contact Toaster Vertical Contact Toaster Wiring Diagram Replacement Parts Parts IdentificationReplacement Parts Description QtyVertical Contact Toaster Vertical Contact Toaster Rev. a 10/99 Optional Parts VCT-25 & VCT-50 Vertical Contact Toaster Vertical Contact Toaster Limited Warranty