VERTICAL CONTACT TOASTER

TROUBLESHOOTING(continued)

Problem

Possible Cause

Corrective Action

 

 

 

Product is over-toasted

Spring tensioner assy(s). or

Replace spring tensioner assy(s). (29, page 20)

or platen heat is too high

tensioner bent or missing.

or tensioners (4, page 24) if damaged or loose.

or drop time is too slow.

 

Replace slide rails (40, page 24) if worn or missing.

(continued).

Bun adjustment controls set

Measure bun thickness and set bun adjustment con-

 

incorrectly.

trols correctly (page 9).

Product is under toasted

Not enough voltage, defec-

Confirm platen temperature reading with a pyrometer

or platen heat is too low

tive power cord, defective

or other temperature source.

or drop time is too fast.

rocker switch.

Check receptacle for correct voltage. See

 

 

 

 

Specifications (page 5).

 

 

With unit plugged in and rocker switch on, check for

 

 

correct voltage into rocker switch. If low or zero volt-

 

 

age, replace power cord. If voltage is correct, check

 

 

for correct voltage out of rocker switch. If low or no

 

 

voltage, replace rocker switch.

 

Wiring problem.

Check all electrical connections for burns, discolor-

 

 

ation or arcing. Replace all connections or compo-

 

 

nents with damaged terminals. Replace all damaged

 

 

wiring with the same (or higher) rated wire.

 

Platen inoperative.

To check platen:

 

 

Use an Ohm meter to test resistance of the platen

 

 

heater (disconnect 1 wire to isolate heater). Correct

 

 

cold resistance for heating element of platen are as

 

 

follows:

 

 

120 Volts, 1750 Watts - 7.8 Ohms

 

 

208 Volts, 2550 Watts - 16.2 Ohms

 

 

230 Volts, 1900 Watts - 26.5 OhmsVCT-20 only. The

 

 

auxiliary heaters are 144.2 Ohms at 208V/300 Watts.

 

Conveyor drive motor inop-

To check drive motor:

 

erative or incorrect conveyor

1.Measure resistance of motor coil. Replace motor

 

motor installed in toaster.

 

 

if coil measures either open circuit or zero resis-

 

 

tance.

 

 

2.Mark the drive motor sprocket and count the turns

 

 

per minute. Correct drive motor speed is nine (9)

 

 

turns per minute for VCT-20; three (3) turns per

 

 

minute for VCT-25; one (1) turn per minute for

 

 

VCT-50.

Product is getting stuck

Bun adjustment controls set

Measure bun thickness and set bun adjustment con-

or conveyor belts stop

incorrectly.

trols correctly (page 9).

when product is toasting.

 

 

Conveyor release sheet not

Clean respective items. Refer to Maintenance

 

 

clean or missing.

Schedule (page 10).

 

 

 

 

 

 

 

16

P/N 1010729 Rev. C 05/04

Image 16
Contents Vertical Contact Toaster Table of Contents Owner InformationService/Technical Assistance Owner InformationImportant Safety Information DeathImportant Safety Information SpecificationsElectrical Cord & Plug Configurations Electrical RatingsSpecifications DimensionsUnpacking InstallationAssembling the Unit Installation Equipment SetupOperation Operating InstructionsMaintenance Maintenance ScheduleCleaning the Release Sheet Conveyor Belts-Removing, Servicing & ReplacingMaintenance Replacing Spring TensionersReplacing Conveyor Motor and Fan Blade Motor Mounting Screw 310P154 Fan BladeTroubleshooting Problem Possible Cause Corrective ActionTroubleshooting Vertical Contact Toaster Vertical Contact Toaster Vertical Contact Toaster Vertical Contact Toaster Wiring Diagram Replacement Parts Parts IdentificationReplacement Parts Description QtyVertical Contact Toaster Vertical Contact Toaster Rev. a 10/99 Optional Parts VCT-25 & VCT-50 Vertical Contact Toaster Vertical Contact Toaster Limited Warranty