Panasonic NN-L530BF, NN-S560BF, NN-S560WF Procedure for Measuring Microwave Energy Leakage

Page 20

PROCEDURE FOR MEASURING MICROWAVE ENERGY LEAKAGE

WARNING

Check for radiation leakage after every servicing. Should the leakage be more than 2 mW/cm2 (1mW/cm2 for Canada) inform PASC, PSC, or PCI immediately.

After repairing or replacing any radiation safety device, keep a written record for future reference, as required by D.H.H.S. and Health and Welfare Canada regulation. This requirement must be strictly observed. In addition, the leakage reading must be recorded on the service repair ticket while in the customer’s home.

(B)Should the radiation leakage be more than 2 mW/cm2 (1mW/cm for Canada) after determining that all parts are in good condition, functioning properly, and genuine replacement parts as listed in this manual have been used, immediately notify PASC, PSC or PCI.

4.At least once a year, have the radiation monitor checked for calibration by its manufacturer.

NOTE: The U.S. Government standard is 5 mW/cm2 while in the customer’s home. 2mW/cm2 stated here is our own voluntary standard. (1mW/cm2 for Canada)

1. Equipment

*Electromagnatic radiation monitor *Glass thermometer 212 OF or 100 OC *600cc glass beaker

2. Procedure for measuring radiation leakage

Note before measuring.

(1)Do not exceed meter full scale deflection. Leakage monitor should initially be set to the highest scale.

(2)To prevent false readings the test probe should be held by the grip portion of the handle only and moved along the shaded area in Figure no faster than 1 inch/sec (2.5cm/sec).

(3)Leakage with the outer panel removed ...... less than 5mW/cm2 .

(4)Leakage for a fully assembled oven with door normally closed

...... less than 2mW/cm2 (1mW/cm 2for Canada).

(5)Leakage for a fully assembled oven [Before the latch switch (primary) is interrupted] while pulling the door ...... less than 2mW/cm2 .

(A)Pour 275￿15cc (9ozss￿1/2oz) of 20O￿5 OC (68O￿9 OF) water in a beaker which is graduated to 600cc, and place in the center of the oven.

(B)Set the radiation monitor to 2450MHz and use it following the manufacturer’s recommended test procedure to assure correct results.

(C)When measuring the leakage, always use the 2 inch (5cm) spacer supplied with the probe.

(D)Tap the start pad or set the timer and with the magnetron oscillating, measure the leakage by holding the probe perpendicular to the surface being measured.

(1)Measurement with the outer panel removed.

Whenever you replace the magnetron, measure for radiation leakage before the outer panel is installed and after all necessary components are replaced or adjusted. Special care should be taken in measur ing around the magnetron.

WARNING

Avoid contacting any high voltage parts.

(2)Measurements with a fully assembled oven.

After all components, including outer panel are fully assembled, measure for radiation leakage around the door periphery, the door viewing window, the exhaust opening and air inlet openings.

3. Record keeping and notification after measurement

(A)After any adjustment or repair to a microwave oven, a leakage read- ing must be taken. Record this leakage reading on the repair ticket even if it is zero.

A copy of this repair ticket and the microwave leakage reading should be kept by repair facility.

WARNING

AVOID CONTACTING ANY HIGH VOLTAGE PARTS.

01-035

MOVE PROBE ALONG SHADED

AREA()AROUND EXHAUST

OPENINGS(as shown)AND AROUND

AIR INLET OPENING

- 19 -

Image 20
Contents Microwave Oven RPH Model refer to the lastContents Inverter Warning Feature Chart Control PanelStop/Reset Pad Operation and Digital Programmer Circuit Test Procedure Operation Scroll DisplayChild Schematic Diagram APH Schematic Diagram CPH Variable power cooking control Inverter Power Supply Circuit NEW H,VVariable Power Cooking Description of Operating SequenceSensor Reheat NN-S560BFAPH/CPH,NN-S560WF APH/CPH Sensor Cooking NN-S560BFAPH/CPH NNExplanation of the Auto Sensor Cooking process Check the grounding Inverter Warnings NEW H.VConfirm after repair Microwave RadiationDisassembly and Parts Replacement Procedure Steam Sensor Door assemblyUntil alignment is achieved Inverter Power Supply U Primary Latch Switch, Secondary Secondary Latch Switch and Power Relay B InterlocksShort Switch & Monitor Membrane key board Membrane switch assemblySteam Sensor and Digital Programmer Circuit 1min. test Measurements and AdjustmentsMeasurement of microwave output Record keeping and notification after measurement Procedure for Measuring Microwave Energy LeakageProcedure for measuring radiation leakage Troubleshooting Guide Symptom Cause CorrectionsDPC Troubleshooting of Inverter Circuit U and Magnetron NEW H.V Trouble Related to Digital Programmer Circuit Exploded View and Parts List Parts List Ref.No Part name & Description Pcs Remarks SetFAN Motor Door Assembly 4T0 Ref.No Part name & Description Pcs Remarks SetEscutheon Base Assembly Packing and Accesories Wiring Material Parts List Digital Programmer CircuitDigital Programmer Circuit Page Page Model for Latin America & Mexico