COMPONENT TEST PROCEDURE

CAUTION NEW. H.V.

1.

High voltage is present at the high voltage terminal of

 

the High Voltage Inverter (U) including aluminum heat

 

sink during any cook cycle.

2.

It is neither necessary nor advisable to attempt mea-

 

surement of the high voltage.

3.

Before touching any oven components, or wiring,

 

always unplug the oven from its power source and

5.Inverter Power Supply (U)for USA only

DO NOT try to REPAIR this H.V. Inverter power supply

(U).Replace as whole H.V. Inverter(U) Unit.

DO NOT TOUCH (HOT/HIGT VOLTAGE)

discharge the high voltage capacitors.

1. Primary Latch Switch, Secondary (Secondary Latch

Switch and Power Relay B) Interlocks.

(A)Unplug the lead connectors to Power Relay B and verify continuity of the power relay B 1-2 terminals.

(B)Unplug lead connectors to Primary Latch Switch and Secondary Latch Switch.

(C)Test the continuity of switches at door opened and closed positions with ohm meter (low scale).

Normal continuity readings should be as follows.

 

Door Closed

Door Opened

Primary Latch Switch

0 (close)

￿(open)

Secondary Latch Switch

0 (close)

￿(open)

Power Relay B

￿(open)

￿(open)

2. Short Switch & Monitor

HEAT SINK

CHOKE COIL

CURRENT

TRANSFORMER

RESISTOR

SAND BAR

PCB

HIGH BOLTAGE

TRANSFORMER

FILM CAPACITORS

VARISTOR

PRIMARY WINDINGS

SECONDARY

WINDINGS

HIGH VOLTAGE

DIODES

(A)Unplug lead wires from Inverter Power Supply (U) primary terminals.

(B)Connect test probes of ohm meter to the disconnected leads which were connected to Inverter Power Supply (U).

(C)Test the continuity of short switch with door opened and closed positions using lowest scale of the ohm meter.

Normal continuity readings should be as follows.

Door Opened

Door Closed

0

￿

3. Magnetron

Continuity checks can only indicate an open filament or a shorted magnetron. To diagnose for an open filament or shorted magnetron.

(A)Isolate magnetron from the circuit by disconnecting the leads.

(B)A continuity check across magnetron filament terminals should indicate one ohm or less.

(C)A continuity check between each filament terminal and magnetron case should read open.

ANTENNA

ANTENNA GASKET

DO NOT TOUCH 4

DANGER HIGH VOLTAGE

Test if failure codes of H97 or H98 appears by doing the following procedure. It is recommended to use an AC line input current Ampere meter for testing.

Test 1

A.Program DPC.

1.Tap Clock

2.Tap TIMER

3.Tap START

4.Tap POWER LEVEL

B.Place 1 liter of water load into oven cavity.

C.Unplug 2 pin H.V. lead wire connector CN703 from magnetron tube.

D.Program oven at High power for 1 minute and press start.

1.After approximately 15 seconds, oven displays H98 and stops oven.

2.During oven operation, input current is approximately 1.0 to 1.7A. If both 1 and 2 are OK, please proceed to test 2.

COOLING FIN

0-1RX1

 

INPUT AMPERE

FAILURE CODE

Unplug CN703

1.0 to 1.7A

H98

.

Test 2.

Continued from Test 1

MAGNETRON CASE

SCALE

A. Unplug 3 pin connector, CN701

B. Set oven at High power for 1 minute and start.

HIGHEST

FILAMENT

OHM

TERMINALS

SCALE

 

04-031M

1.After approximately 27 seconds, oven displays H97 and stops oven.

2.During oven operation, input current is approximately 0.4 to 0.8A

 

INPUT AMPERE

FAILURE CODE

Unplug CN701

0.4 to 0.8A

H97

 

 

 

If both 1 and 2 are OK, the Inverter Power Supply (U) can be determined OK.

4.Membrane key board (Membrane switch assembly)

Check continuity between switch terminals, by tapping an appropri- ate pad on the key board. The contacts assignment of the respective pads on the key board is as shown in digital programmer circuit.

- 16 -

Image 17
Contents RPH Model refer to the last Microwave OvenContents Inverter Warning Control Panel Feature ChartStop/Reset Pad Operation Scroll Display Operation and Digital Programmer Circuit Test ProcedureChild Schematic Diagram APH Schematic Diagram CPH Inverter Power Supply Circuit NEW H,V Variable power cooking controlVariable Power Cooking Description of Operating SequenceSensor Reheat NN-S560BFAPH/CPH,NN-S560WF APH/CPH Sensor Cooking NN-S560BFAPH/CPH NNExplanation of the Auto Sensor Cooking process Inverter Warnings NEW H.V Check the groundingMicrowave Radiation Confirm after repairDisassembly and Parts Replacement Procedure Steam Sensor Door assemblyUntil alignment is achieved Inverter Power Supply U Switch and Power Relay B Interlocks Primary Latch Switch, Secondary Secondary LatchShort Switch & Monitor Membrane key board Membrane switch assemblySteam Sensor and Digital Programmer Circuit 1min. test Measurements and AdjustmentsMeasurement of microwave output Record keeping and notification after measurement Procedure for Measuring Microwave Energy LeakageProcedure for measuring radiation leakage Symptom Cause Corrections Troubleshooting GuideDPC Troubleshooting of Inverter Circuit U and Magnetron NEW H.V Trouble Related to Digital Programmer Circuit Exploded View and Parts List Ref.No Part name & Description Pcs Remarks Set Parts ListFAN Motor 4T0 Ref.No Part name & Description Pcs Remarks Set Door AssemblyEscutheon Base Assembly Packing and Accesories Wiring Material Digital Programmer Circuit Parts ListDigital Programmer Circuit Page Page Model for Latin America & Mexico