CONVERSION OF GAS

Your cooker is designed to work with natural gas, propane or butane. It is not designed for butane or propane air.

The LPG conversion kit is available from your Service Force Centre and must be fitted by a Corgi Registered engineer.

For changing the gas type it is necessary to:

replace the nozzles (hob, oven and grill);

adjust the minimum level (hob and oven);

adjust the primary air (oven and grill);

check the gas connection.

Stick the label supplied with the appliance (in the nozzles bag) corresponding to the gas type utilised.

Replace the nozzles of the hob burners Every appliance has spare nozzles for every type of gas. The whole length of every nozzle is marked in millimetres on the nozzle.

Hob burners

Remove the pan support;

Remove the caps and the burner crowns;

Using a No 7 socket spanner unscrew the nozzles and replace them with those required for the type of gas in use (see table no. 1).

Reassemble the parts following the same procedure in reverse.

These burners do not need any primary air regulation.

Adjustment of minimum level for the hob burners

The burner is correctly adjusted when the flame is stable silent and goes out without any noise.

When changing the type of gas check that the minimum level is correct. The air admission is correct when the flame is about 4 mm in length.

The top burners do not need adjustment of primary air.

Check that, turning the knob quickly from the maximum position to the minimum one, the flame does not go out.

22

Image 22
Contents GSV 5050 W Contents Service Important Safety InformationChild Safety During UseDescription of the Appliance Model GSV 5050 WTechnical Features Oven Safety device Using the ApplianceUsing the Oven Before the First Use CookerIgnition UseCooking in the Oven Storage CompartmentCondensation and steam Hints and TipsCookware Grilling Using the GrillGrill burner ignition Grilling meatIgnition of the burners Using the HobHob Burners Extinguishing of burnersAccessories delivered with the appliance Selecting the Correct burnerExternal cleaning Maintenance and CleaningCleaning materials Oven DoorHob Oven CavityBurners Symptoms Solutions Something not WorkingService and Spare Parts Customer CareEuropean Guarantee Guarantee ConditionsStandard Guarantee Conditions ExclusionsInstructions for the Installer Technical DataInstallation Positioning Location Ventilation Levelling Left Hand Connection from front GAS ConnectionsRigid Connection Page Conversion of GAS Adjustment of minimum level for the hob burnersHob burners Grill burner Table no.2 Gas type Air adjusting mmReplace the nozzles of the oven burners Oven burner GrillFlame adjustment Oven burners Adjustment of minimum level Oven burner