FCT technical data

GSM AIR INTERFACE

Frequency Bands: Triple-Band E-GSM 900, GSM 1800 and GSM 1900

E-GSM 900

Frequencies: TX 880-915 MHz, RX 925-960 MHz

RF power: Maximum 2 W (33 dBm), Power class 4

GSM1800

Frequencies: TX 1710-1785 MHz,

RX 1805-1880 MHz

RF power: Maximum 1 W (30 dBm),

Power class 1

GSM1900

Frequencies: TX 1850-1910 MHz,

RX 1930-1990 MHz

RF power: Maximum 1 W (30 dBm),

Power class 1

Data capabilities: multislot GPRS Class B and HSCSD (Data rates depend on GSM operator services)

Speech codecs: Full Rate, Enhanced Full Rate and Half Rate

FCT INTERFACES

Telephones: RJ11 (a/b 2-wire line); fixed telephone interface

RS232 port: DB-9 Serial COM interface

GSM antenna: SMA plug- female (50 ohm)

SIM card: Small plug-in card, 3V or 5V type

Input Vdc: 7.5 Vdc; 0.8 A (connector: EIAJ RC-5320A class 4, male)

TELEPHONE INTERFACES

Telephones: Speech

Analog Fax: Group 3 Fax transmission

Analog Data: V.90, V.34, V.32bis, V.32, V.22bis, V.22, V.23, V.21, Bell 212A & 103

CLI: ETSI DTMF and V.23; Bellcore FSK

Line Impedance: 600 ohm (default)

Loop Current: 25 mA (off-hook)

Open loop voltage: 48 V (on-hook)

Loop resistance: < 650 ohm (off-hook)

Ringing voltage: 45 Vrms

Ring Load: 3 REN; up to 3 telephone devices

FCT technical data

37

Image 38
Contents Page Page Page Content More than one call call wait, call holdTroubleshooting and FCT Indicators Regulatory Information Ericsson F221m Triple band GSM E-GSM 900, GSM 1800, GSM F221mSupplied parts External connectors and light indicators SIM cardInstalling the FCT as a telephone line ConnectionsConnect the antenna AssemblyPreparing your FCT Place the front cover back in its previous positionConnect a fixed telephone to the FCT telephone line Switch on the FCTConnect a telephone to the FCT Enter PINNetwork search Installing the FCT on the wallLocation Testing FCT LocationWall mounting Do not install the FCT on walls or rooms thatContain large amounts of metal, steel or wiring Connecting fixed line devices Tip if your house or company is already wired withChecking the calls quality Checking connectionsTip if any of the telephones has not been ringing Using telephones Using CLI displays BellcoreReceiving a fax Using fax machinesSending a fax You can choose between two connection methods Using PCsGprs data access type GSM data access type SIM card must support GSM dataUsing PCs Diverting calls call forward Advanced featuresChanging volume With Function … Dial … You will hear… Restricting calls call barring To manage restriction of calls … Making a second call Call waiting serviceTo manage Call waiting Dial… You will hear… Function… Receiving a second callConference calls multiparty Explicit call transferDial Pos Dialing … Phonebook abbreviated dialingDelete #51*Pos*1# Beeps FCT memory Check position Controlling call time minute minder Sending tone signalsVoice mail Dial… You will hear…Two voice lines alternate line service To manage the hot line … Dial … You will hear…To manage your SIM card To manage Alternate line Dial … You will hear…SIM card security To unblock your SIM cardTo unblock your SIM card while changing your PIN Number of green Network signal strength Troubleshooting and FCT indicatorsLight indicators Red light Power supply situationSimultaneous flashing Alarm status Do this … FCT is connected to Audible tones Tone Name Nature It meansSpeech codecs Full Rate, Enhanced Full Rate and Half Rate FCT technical dataFrequency Bands Triple-Band E-GSM 900, GSM 1800 and GSM Power Supply included Antenna includedAntennas AccessoriesDA20 Display Adapter BatteriesFCT Data Reference manual DC/DC Power AdapterAA batteries holder size 99.01 mm x 51.69 mm is provided ‘Telephone number’ field enter *98#, then click ‘Next’ Annex PC data configurationsWindows 98 Gprs set-up Click on ‘Finish’ Annex PC data configurations Windows NT Gprs set-up Annex PC data configurations Annex PC data configurations Annex PC data configurations Annex PC data configurations Antenna care Safe and efficient useProduct care Potentially explosive atmospheres Radio frequency energyElectronic devices Lead Battery Power supplyBattery information ChildrenAccessing the battery compartment Do not expose the battery to liquidDisposing of the battery AA batteriesEricsson Warranty Limited warrantyLimited warranty conditions What Ericsson will doLimited Warranty Ericsson type 0130101-BV Regulatory informationDeclare under our sole responsibility that our product We fulfil the requirements of the R&TTE Directive 99/5/ECDefinitions DefinitionsPage Ericsson España, S. a