Bunn ULTRA-1 manual 120V Compressors 230V Compressors

Page 28

SERVICE (cont.)

COMPRESSOR (AMERICOLD) (ULTRA-2)

FIG. 14 COMPRESSOR ASSY

Location:

The compressor assy is located inside the front of the dispenser chassis.

1

2

3

4

5

120V COMPRESSORS

1 2

3

4

5

6

230V COMPRESSORS

 

 

FIG. 15 COMPRESSOR ELECTRICAL COMPONENTS

1.Compressor Start Relay

2.Thermal Overload Protector

3.Overload Protector Retainer

4.Compressor Terminal Cover

5.Terminal Cover Retainer

6.Compressor Run Capacitor

Test Procedures:

WARNING: The compressor start capacitor must be properly discharged before proceeding. This is most commonly done on low voltage capacitors by shorting across the terminals with a screwdriver.

Compressor Start Relay: Refer to FIG. 15

1.Disconnect the dispenser from the power source.

2.Remove compressor terminal cover retainer (5) and compressor terminal cover (4).

3.Connect a voltmeter across the white wire and the white/ orange wire. Connect the dispenser to the power source. Verify the dispenser is in “ICE” or “CHILL” mode.

The indication must be:

(a)120 volts ac for two wire 120 volt models or

(b)230 volts ac for two wire 230 volt models.

5.Disconnect the dispenser from the power source.

If voltage is present as described, proceed to the following test procedures.

If voltage is not present as described, refer to the Relay and check the relay.

6.Disconnect the two black wires from the compressor start relay.

7.Remove relay from the compressor.

8.Check for continuity across the upper left terminal and the right pin socket on the rear of the relay.

If continuity is present as described, the compressor start relay is operating properly.

If continuity is not present as described, replace relay.

Compressor:

1.With the compressor start relay (1) removed, disconnect the black wire from the compressor.

2.Check for continuity across the terminal on the compres- sor and the left pin on the compressor.

If continuity is present as described, the electrical part of the compressor is operating properly.

If continuity is not present as described, replace the com- pressor.

Thermal Overload Protector:

1.Check for continuity across the terminals on the thermal overload protector (2).

If continuity is present as described, the thermal overload protector is operating properly.

If continuity is not present as described, replace the thermal overload protector.

28

41084 102709

 

Image 28
Contents ULTRA-1 ULTRA-2 Phone 217 529-6601 FAX 217BUNN-O-MATIC Commercial Product Warranty Contents User NoticesIntroduction Temp & Torque Screen Operating Controls ULTRA-1 Switch upper left corner of the control pad Operating Controls ULTRA-2Recommended Daily Cleaning ULTRA-2 shown Other and disconnect from Be taken when handling HopperFrom the rear of the drum Under spring tension. Spread One side of the handle first, thenRecommended Daily Cleaning Drums and press the sealsFirmly into place as shown Auger noseSanitizing Procedure Auto-fill Cleaning Instructions With Brixing Pump InstalledMaterials required Preventive Maintenance Normal OperationRequired Regular Maintenance Semi Annual Kit ContentsInstructions DescriptionRequired Regular Maintenance No Power TroubleshootingBoard Troubleshooting Chills but Won’t freeze Set into DAY modeSet into ICE mode Is display showing Done Adjust CleanTroubleshooting No cooling At all Yes Dirty? Check fan Have a certifiedAdjust thickness Screen higher Troubleshooting Freezes, but not Thick enoughBrix ratio Too much Troubleshooting Noise Auger jumping Check fanDrum alignment Check auger shaft bushings Auger won’t turnTroubleshooting Torque Sensor ErrorTorque Sensor Error Torque Sensor Shorted Torque Sensor OpenTemperature Sensor Shorted Troubleshooting Temperature Sensor ErrorTemperature Sensor Open Troubleshooting Clean Filter Messages Filter Needs CleaningFreezing is Disabled Monthly reminderService Component Access PanelsAuger Motors SERVICEcontMotor Coil Resistance Auger Motor Capacitor Auger Motor CapacitorsAuger Shaft Assembly Auger Shaft AssemblyService Auger Shaft ASSEMBLYcont Remove and clean condenser air filter, FigTest Procedures Remove the wires from the circuit breakerCircuit Breaker Location120V Compressors 230V Compressors Compressor Start Relay Terminals Service Compressor Embraco ULTRA-2 Compressor AssyModel T-2155 Service Compressor Embraco ULTRA-2Model T-2168 Secure compressor to the dispenser chassis using four Compressor Appliances ULTRA-1 Compressor ThermalRelay Terminals Service Service Compressor Danfoss ULTRA-1B Compressor Capacitor Terminals Service Relay or Contactor on Early Models Control Board Control Board ULTRA-2Cooling Drum Alignment Cooling Drum Shipping SupportUse cable ties to secure wires away from fan blades Front of the condenser Test ProceduresFAN ULTRA-2 FAN ULTRA-1 FANHOT GAS Temperature Sensor Alternate TestLamp Cord Wires Lamp Cord AssyLamp Cord Connector Lamp Cord ConnectorLamp HOLDER/SOCKET Assembly Lamp HOLDER/SOCKET AssemblyLamp Relay ULTRA-2 ULTRA-1Membrane Switch ULTRA-2 Ribbon CableMembrane Switch ULTRA-1 Refer to and connect the ribbon cable to the Control BoardSolenoids WHI from Main HarnessTemperature Sensor Temperature SensorTorque Sensor Circuit Board Remove the cover and set aside for reassemblyDo not Turn on Augers Transformer LoadCoolant Schematic ULTRA-1 Coolant Schematic ULTRA-2 ULTRA-1 Triacs Triac MAP for ULTRA-1TH1 & MOV4 Controls Auger Liquid AUTO-FILL Board ULTRA-2 Triacs Triac Maps for ULTRA-2TH6 & MOV6 Controls Right Auger Input and Output Chart ULTRA-1 41084 Input and Output Chart ULTRA-2 41084 41084
Related manuals
Manual 14 pages 46.12 Kb Manual 22 pages 47.89 Kb Manual 17 pages 28.06 Kb Manual 22 pages 35.42 Kb

ULTRA-1 specifications

The Bunn ULTRA-1 is a state-of-the-art coffee brewing system designed for commercial use, offering an unmatched combination of speed, efficiency, and flavor extraction. This single-serve coffee brewer is tailored for businesses that require high-quality coffee brews in a fast-paced environment, such as cafes, restaurants, and office kitchens.

One of the standout features of the Bunn ULTRA-1 is its ability to brew up to 14 different cup sizes, accommodating various customer preferences. This flexibility allows operators to serve everything from small espresso shots to larger coffee servings, making it a versatile addition to any beverage-serving establishment. At the heart of this brewing system is Bunn's patented brewing technology, which ensures precise water temperature and ideal brew time, optimizing the extraction process for a full-bodied flavor profile.

The ULTRA-1 is equipped with a large, easy-to-read LCD screen that provides real-time feedback, allowing users to monitor brewing progress, select cup sizes, and customize brewing parameters. This intuitive interface simplifies operation, reducing the learning curve for new staff members and enhancing overall efficiency during peak hours.

Another innovative aspect of the Bunn ULTRA-1 is its advanced thermal carafe system, which keeps brewed coffee at the optimal serving temperature without the need for a traditional warming plate. This technology helps preserve the coffee's rich flavor and aroma by preventing it from becoming bitter or stale due to prolonged exposure to heat.

The ULTRA-1 emphasizes ease of maintenance with its removable brew chamber and drip tray, allowing for quick cleaning and routine upkeep. Additionally, the brewer features a self-diagnostic system, alerting operators to any potential issues, further minimizing downtime.

From its sleek design to its robust construction, the Bunn ULTRA-1 combines aesthetics and durability, making it a reliable choice for any coffee-centric business. The compact design ensures it can fit on counters without taking up excessive space, while its stainless steel components provide longevity and resistance to wear and tear.

In conclusion, the Bunn ULTRA-1 stands out in the crowded market of commercial coffee brewers due to its advanced technology, versatility, and user-friendly features. It is designed to meet the demands of modern coffee service while ensuring that every cup brewed meets the highest standards for taste and quality.