Bunn ULTRA-1 manual Contents, User Notices

Page 3

CONTENTS

 

Warranty

2

User Notices

3

Site Preparation

3

Introduction

4

Operating Controls

6

Preventive Maintenance

 

Recommended Cleaning

8

Auto-fill Cleaning Instructions

10

Preventive Maintenance Schedule

11

Troubleshooting

14

Service

 

Access Panels

22

Auger Motors

23

Auger Motor Capacitors

24

Auger Shaft Assembly

25

Circuit Breaker

27

Compressor

28,31,34,37

Relay (or Contactor on Early Models)

39

Control Board

40

Cooling Drum Alignment

41

Fan

42,43

Hot Gas Sensor

44

Lamp Cord Assembly

45

Lamp Cord Connector

46

Lamp Holder/Socket Assembly

47

Lamp Relay

48

Membrane Switch

49,50

Solenoids

51

Temperature Sensor Assembly

52

Torque Sensor Circuit Board

53

Transformer

54

Coolant Schematics

55

Electrical Schematics

57

USER NOTICES

All notices on this equipment are written for your protection. All notices are to be kept in good condition. Replace any unreadable or damaged labels.

Site preparation

The dispenser must have at least four inches of space behind it. This space is needed for airflow, air filter removal, and cleaning. Minimal clearance is required between the dispenser sides and the wall or another appli- ance. The dispenser performs better if not placed near any heating appliance. Leave some space so the dispenser can be moved for cleaning.

3

41084 102709

 

Image 3
Contents Phone 217 529-6601 FAX 217 ULTRA-1 ULTRA-2BUNN-O-MATIC Commercial Product Warranty User Notices ContentsIntroduction Temp & Torque Screen Operating Controls ULTRA-1 Operating Controls ULTRA-2 Switch upper left corner of the control padOne side of the handle first, then Recommended Daily Cleaning ULTRA-2 shownOther and disconnect from Be taken when handling Hopper From the rear of the drum Under spring tension. SpreadAuger nose Recommended Daily CleaningDrums and press the seals Firmly into place as shownAuto-fill Cleaning Instructions With Brixing Pump Installed Sanitizing ProcedureMaterials required Normal Operation Preventive MaintenanceDescription Required Regular Maintenance Semi AnnualKit Contents InstructionsRequired Regular Maintenance Troubleshooting No PowerBoard Done Adjust Clean Troubleshooting Chills but Won’t freezeSet into DAY mode Set into ICE mode Is display showingYes Dirty? Check fan Have a certified Troubleshooting No cooling At allTroubleshooting Freezes, but not Thick enough Adjust thickness Screen higherBrix ratio Too much Auger won’t turn Troubleshooting NoiseAuger jumping Check fan Drum alignment Check auger shaft bushingsTorque Sensor Shorted Torque Sensor Open TroubleshootingTorque Sensor Error Torque Sensor ErrorTroubleshooting Temperature Sensor Error Temperature Sensor ShortedTemperature Sensor Open Monthly reminder Troubleshooting Clean Filter MessagesFilter Needs Cleaning Freezing is DisabledComponent Access Panels ServiceSERVICEcont Auger MotorsMotor Coil Resistance Auger Motor Capacitors Auger Motor CapacitorAuger Shaft Assembly Auger Shaft AssemblyRemove and clean condenser air filter, Fig Service Auger Shaft ASSEMBLYcontLocation Test ProceduresRemove the wires from the circuit breaker Circuit Breaker120V Compressors 230V Compressors Compressor Start Relay Terminals Service Compressor Assy Compressor Embraco ULTRA-2Service Compressor Embraco ULTRA-2 Model T-2155Model T-2168 Secure compressor to the dispenser chassis using four Compressor Thermal Compressor Appliances ULTRA-1Relay Terminals Service Service Compressor Danfoss ULTRA-1B Compressor Capacitor Terminals Service Relay or Contactor on Early Models Control Board ULTRA-2 Control BoardCooling Drum Shipping Support Cooling Drum AlignmentFront of the condenser Test Procedures Use cable ties to secure wires away from fan bladesFAN ULTRA-2 FAN FAN ULTRA-1Alternate Test HOT GAS Temperature SensorLamp Cord Assy Lamp Cord WiresLamp Cord Connector Lamp Cord ConnectorLamp HOLDER/SOCKET Assembly Lamp HOLDER/SOCKET AssemblyULTRA-2 ULTRA-1 Lamp RelayRibbon Cable Membrane Switch ULTRA-2Refer to and connect the ribbon cable to the Control Board Membrane Switch ULTRA-1WHI from Main Harness SolenoidsTemperature Sensor Temperature SensorRemove the cover and set aside for reassembly Torque Sensor Circuit BoardDo not Turn on Augers Load TransformerCoolant Schematic ULTRA-1 Coolant Schematic ULTRA-2 Triac MAP for ULTRA-1 ULTRA-1 TriacsTH1 & MOV4 Controls Auger Triac Maps for ULTRA-2 Liquid AUTO-FILL Board ULTRA-2 TriacsTH6 & MOV6 Controls Right Auger Input and Output Chart ULTRA-1 41084 Input and Output Chart ULTRA-2 41084 41084
Related manuals
Manual 14 pages 46.12 Kb Manual 22 pages 47.89 Kb Manual 17 pages 28.06 Kb Manual 22 pages 35.42 Kb

ULTRA-1 specifications

The Bunn ULTRA-1 is a state-of-the-art coffee brewing system designed for commercial use, offering an unmatched combination of speed, efficiency, and flavor extraction. This single-serve coffee brewer is tailored for businesses that require high-quality coffee brews in a fast-paced environment, such as cafes, restaurants, and office kitchens.

One of the standout features of the Bunn ULTRA-1 is its ability to brew up to 14 different cup sizes, accommodating various customer preferences. This flexibility allows operators to serve everything from small espresso shots to larger coffee servings, making it a versatile addition to any beverage-serving establishment. At the heart of this brewing system is Bunn's patented brewing technology, which ensures precise water temperature and ideal brew time, optimizing the extraction process for a full-bodied flavor profile.

The ULTRA-1 is equipped with a large, easy-to-read LCD screen that provides real-time feedback, allowing users to monitor brewing progress, select cup sizes, and customize brewing parameters. This intuitive interface simplifies operation, reducing the learning curve for new staff members and enhancing overall efficiency during peak hours.

Another innovative aspect of the Bunn ULTRA-1 is its advanced thermal carafe system, which keeps brewed coffee at the optimal serving temperature without the need for a traditional warming plate. This technology helps preserve the coffee's rich flavor and aroma by preventing it from becoming bitter or stale due to prolonged exposure to heat.

The ULTRA-1 emphasizes ease of maintenance with its removable brew chamber and drip tray, allowing for quick cleaning and routine upkeep. Additionally, the brewer features a self-diagnostic system, alerting operators to any potential issues, further minimizing downtime.

From its sleek design to its robust construction, the Bunn ULTRA-1 combines aesthetics and durability, making it a reliable choice for any coffee-centric business. The compact design ensures it can fit on counters without taking up excessive space, while its stainless steel components provide longevity and resistance to wear and tear.

In conclusion, the Bunn ULTRA-1 stands out in the crowded market of commercial coffee brewers due to its advanced technology, versatility, and user-friendly features. It is designed to meet the demands of modern coffee service while ensuring that every cup brewed meets the highest standards for taste and quality.