Bunn manual Membrane Switch ULTRA-1, Refer to and connect the ribbon cable to the Control Board

Page 50

SERVICE (cont.)

MEMBRANE SWITCH (ULTRA-1)

FIG. 56 MEMBRANE SWITCH

Location:

The membrane switch is located on the front panel.

Test Procedures:

NOTE: Before continuing, check that the ribbon cable is properly connected to the control board and not a pin off in either direction.

1.Disconnect the dispenser from the power source.

2.Remove the right and left side panels.

3.Remove the front panel and disconnect ribbon cable.

4.Check for continuity of the switches using pin #2 as common.

#2 - #1 (shield) no continuity #2 - #3 (I/O)

#2 - #4 (ULTRA)

#2 - #5 (GOURMET) #2 - #6 (ICE)

#2 - #7 (ICE/CHILL/OFF) #2 - #8 (Auger Motor)

If continuity is not present when the appropriate switch is pressed, the Membrane Switch must be replaced.

If continuity is present, check the short harness going to J11 on the Control Board.

Removal and Replacement:

1.Disconnect the dispenser from the power source.

2.Remove right and left side panels.

3.Remove front panel and disconnect ribbon cable.

4.Peel the old Membrane Swith off the front panel and discard. Clean any remaining adhesive from front panel with mineral spirits and then alcohol.

5.Remove protective paper backing from back side of new Membrane Switch.

6.Guide ribbon cable through narrow slot in panel. Carefully position new Membrane Switch on panel, while centering display window to opening.

7.Refer to Fig. 57 and connect the ribbon cable to the Control Board.

 

MEMBRANE

 

 

SWITCH

SHIELD

 

 

 

1

 

 

 

8

POWER

ULTRA

GOURMET

ICE

 

 

FIG. 57 MEMBRANE SWITCH

 

1

 

FIG. 58 MEMBRANE SWITCH and RIBBON CABLE

50

41084 102709

 

Image 50
Contents ULTRA-1 ULTRA-2 Phone 217 529-6601 FAX 217BUNN-O-MATIC Commercial Product Warranty Contents User NoticesIntroduction Temp & Torque Screen Operating Controls ULTRA-1 Switch upper left corner of the control pad Operating Controls ULTRA-2From the rear of the drum Under spring tension. Spread Recommended Daily Cleaning ULTRA-2 shownOther and disconnect from Be taken when handling Hopper One side of the handle first, thenFirmly into place as shown Recommended Daily CleaningDrums and press the seals Auger noseMaterials required Auto-fill Cleaning Instructions With Brixing Pump InstalledSanitizing Procedure Preventive Maintenance Normal OperationInstructions Required Regular Maintenance Semi AnnualKit Contents DescriptionRequired Regular Maintenance Board TroubleshootingNo Power Set into ICE mode Is display showing Troubleshooting Chills but Won’t freezeSet into DAY mode Done Adjust CleanTroubleshooting No cooling At all Yes Dirty? Check fan Have a certifiedBrix ratio Too much Troubleshooting Freezes, but not Thick enoughAdjust thickness Screen higher Drum alignment Check auger shaft bushings Troubleshooting NoiseAuger jumping Check fan Auger won’t turnTorque Sensor Error TroubleshootingTorque Sensor Error Torque Sensor Shorted Torque Sensor OpenTemperature Sensor Open Troubleshooting Temperature Sensor ErrorTemperature Sensor Shorted Freezing is Disabled Troubleshooting Clean Filter MessagesFilter Needs Cleaning Monthly reminderService Component Access PanelsMotor Coil Resistance SERVICEcontAuger Motors Auger Motor Capacitor Auger Motor CapacitorsAuger Shaft Assembly Auger Shaft AssemblyService Auger Shaft ASSEMBLYcont Remove and clean condenser air filter, FigCircuit Breaker Test ProceduresRemove the wires from the circuit breaker Location120V Compressors 230V Compressors Compressor Start Relay Terminals Service Compressor Embraco ULTRA-2 Compressor AssyModel T-2168 Service Compressor Embraco ULTRA-2Model T-2155 Secure compressor to the dispenser chassis using four Compressor Appliances ULTRA-1 Compressor ThermalRelay Terminals Service Service Compressor Danfoss ULTRA-1B Compressor Capacitor Terminals Service Relay or Contactor on Early Models Control Board Control Board ULTRA-2Cooling Drum Alignment Cooling Drum Shipping SupportFAN ULTRA-2 Front of the condenser Test ProceduresUse cable ties to secure wires away from fan blades FAN ULTRA-1 FANHOT GAS Temperature Sensor Alternate TestLamp Cord Wires Lamp Cord AssyLamp Cord Connector Lamp Cord ConnectorLamp HOLDER/SOCKET Assembly Lamp HOLDER/SOCKET AssemblyLamp Relay ULTRA-2 ULTRA-1Membrane Switch ULTRA-2 Ribbon CableMembrane Switch ULTRA-1 Refer to and connect the ribbon cable to the Control BoardSolenoids WHI from Main HarnessTemperature Sensor Temperature SensorDo not Turn on Augers Remove the cover and set aside for reassemblyTorque Sensor Circuit Board Transformer LoadCoolant Schematic ULTRA-1 Coolant Schematic ULTRA-2 TH1 & MOV4 Controls Auger Triac MAP for ULTRA-1ULTRA-1 Triacs TH6 & MOV6 Controls Right Auger Triac Maps for ULTRA-2Liquid AUTO-FILL Board ULTRA-2 Triacs Input and Output Chart ULTRA-1 41084 Input and Output Chart ULTRA-2 41084 41084
Related manuals
Manual 14 pages 46.12 Kb Manual 22 pages 47.89 Kb Manual 17 pages 28.06 Kb Manual 22 pages 35.42 Kb

ULTRA-1 specifications

The Bunn ULTRA-1 is a state-of-the-art coffee brewing system designed for commercial use, offering an unmatched combination of speed, efficiency, and flavor extraction. This single-serve coffee brewer is tailored for businesses that require high-quality coffee brews in a fast-paced environment, such as cafes, restaurants, and office kitchens.

One of the standout features of the Bunn ULTRA-1 is its ability to brew up to 14 different cup sizes, accommodating various customer preferences. This flexibility allows operators to serve everything from small espresso shots to larger coffee servings, making it a versatile addition to any beverage-serving establishment. At the heart of this brewing system is Bunn's patented brewing technology, which ensures precise water temperature and ideal brew time, optimizing the extraction process for a full-bodied flavor profile.

The ULTRA-1 is equipped with a large, easy-to-read LCD screen that provides real-time feedback, allowing users to monitor brewing progress, select cup sizes, and customize brewing parameters. This intuitive interface simplifies operation, reducing the learning curve for new staff members and enhancing overall efficiency during peak hours.

Another innovative aspect of the Bunn ULTRA-1 is its advanced thermal carafe system, which keeps brewed coffee at the optimal serving temperature without the need for a traditional warming plate. This technology helps preserve the coffee's rich flavor and aroma by preventing it from becoming bitter or stale due to prolonged exposure to heat.

The ULTRA-1 emphasizes ease of maintenance with its removable brew chamber and drip tray, allowing for quick cleaning and routine upkeep. Additionally, the brewer features a self-diagnostic system, alerting operators to any potential issues, further minimizing downtime.

From its sleek design to its robust construction, the Bunn ULTRA-1 combines aesthetics and durability, making it a reliable choice for any coffee-centric business. The compact design ensures it can fit on counters without taking up excessive space, while its stainless steel components provide longevity and resistance to wear and tear.

In conclusion, the Bunn ULTRA-1 stands out in the crowded market of commercial coffee brewers due to its advanced technology, versatility, and user-friendly features. It is designed to meet the demands of modern coffee service while ensuring that every cup brewed meets the highest standards for taste and quality.