Bunn ULTRA-1 manual Service Compressor Embraco ULTRA-2, Model T-2155, Model T-2168

Page 32

SERVICE (cont.)

COMPRESSOR (EMBRACO) (ULTRA-2) (cont.)

Removal and Replacement:

Compressor Start Relay: Refer to FIG. 20

1.Disconnect the wires from the compressor start re- lay.

3.Pull relay (1) off of the compressor pins and discard.

4.Push new relay onto the compressor pins.

5.Refer to Fig. 21 and reconnect the wires.

6.Reinstall terminal cover (4) and cover retainer (5).

White from Main Harness

6.Install retainer (3) on new overload protector (2).

7.Install retainer (3) and overload protector (2) on the compressor terminal bracket.

8.Refer to Fig. 22 and reconnect the thermal overload protector wires.

9.Reinstall terminal cover (4) and cover retainer (5).

WHI/ORN from

Main Harness

BLK to Compressor

Plug directly to two lower terminals on Compressor

Model T-2155

FIG. 22 THERMAL OVERLOAD

PROTECTOR TERMINALS

Compressor Run Capacitor: Refer to FIG. 20

P1339

Black from Run Capacitor White from Main Harness

Black from Run Capacitor

White from Main Harness

1.Disconnect the run capacitor leads.

2.Remove the nut securing the run capacitor to the capaci- tor mounting bracket.

3.Remove run capacitor and discard.

4.Place new run capacitor on capacitor mounting bracket and secure nut.

5.Refer to Fig. 23 and reconnect the wires.

Model T-2168

P1338

FIG. 21 COMPRESSOR START RELAY

TERMINALS

Compressor Thermal Overload Protector: Refer to FIG. 20

1.Remove terminal cover retainer (5) and terminal cover

(4).

2.Disconnect the WHI/ORN wire of the harness from the thermal overload protector.

3.Disconnect the BLK wire from the Compressor’s upper terminal.

4.Remove overload protector retainer (3) and thermal overload protector (2) as an assembly.

5.Remove retainer (3) from overload protector (2) and discard overload protector.

BLK to Start Relay T1 BLK to Start Relay T3

P1816

FIG. 23 COMPRESSOR RUN CAPACITOR

TERMINALS

32

41084 102709

 

Image 32
Contents ULTRA-1 ULTRA-2 Phone 217 529-6601 FAX 217BUNN-O-MATIC Commercial Product Warranty Contents User NoticesIntroduction Temp & Torque Screen Operating Controls ULTRA-1 Switch upper left corner of the control pad Operating Controls ULTRA-2Recommended Daily Cleaning ULTRA-2 shown Other and disconnect from Be taken when handling HopperFrom the rear of the drum Under spring tension. Spread One side of the handle first, thenRecommended Daily Cleaning Drums and press the sealsFirmly into place as shown Auger noseMaterials required Auto-fill Cleaning Instructions With Brixing Pump InstalledSanitizing Procedure Preventive Maintenance Normal OperationRequired Regular Maintenance Semi Annual Kit ContentsInstructions DescriptionRequired Regular Maintenance Board TroubleshootingNo Power Troubleshooting Chills but Won’t freeze Set into DAY modeSet into ICE mode Is display showing Done Adjust CleanTroubleshooting No cooling At all Yes Dirty? Check fan Have a certifiedBrix ratio Too much Troubleshooting Freezes, but not Thick enoughAdjust thickness Screen higher Troubleshooting Noise Auger jumping Check fanDrum alignment Check auger shaft bushings Auger won’t turnTroubleshooting Torque Sensor ErrorTorque Sensor Error Torque Sensor Shorted Torque Sensor OpenTemperature Sensor Open Troubleshooting Temperature Sensor ErrorTemperature Sensor Shorted Troubleshooting Clean Filter Messages Filter Needs CleaningFreezing is Disabled Monthly reminderService Component Access PanelsMotor Coil Resistance SERVICEcontAuger Motors Auger Motor Capacitor Auger Motor CapacitorsAuger Shaft Assembly Auger Shaft AssemblyService Auger Shaft ASSEMBLYcont Remove and clean condenser air filter, FigTest Procedures Remove the wires from the circuit breakerCircuit Breaker Location120V Compressors 230V Compressors Compressor Start Relay Terminals Service Compressor Embraco ULTRA-2 Compressor AssyModel T-2168 Service Compressor Embraco ULTRA-2Model T-2155 Secure compressor to the dispenser chassis using four Compressor Appliances ULTRA-1 Compressor ThermalRelay Terminals Service Service Compressor Danfoss ULTRA-1B Compressor Capacitor Terminals Service Relay or Contactor on Early Models Control Board Control Board ULTRA-2Cooling Drum Alignment Cooling Drum Shipping SupportFAN ULTRA-2 Front of the condenser Test ProceduresUse cable ties to secure wires away from fan blades FAN ULTRA-1 FANHOT GAS Temperature Sensor Alternate TestLamp Cord Wires Lamp Cord AssyLamp Cord Connector Lamp Cord ConnectorLamp HOLDER/SOCKET Assembly Lamp HOLDER/SOCKET AssemblyLamp Relay ULTRA-2 ULTRA-1Membrane Switch ULTRA-2 Ribbon CableMembrane Switch ULTRA-1 Refer to and connect the ribbon cable to the Control BoardSolenoids WHI from Main HarnessTemperature Sensor Temperature SensorDo not Turn on Augers Remove the cover and set aside for reassemblyTorque Sensor Circuit Board Transformer LoadCoolant Schematic ULTRA-1 Coolant Schematic ULTRA-2 TH1 & MOV4 Controls Auger Triac MAP for ULTRA-1ULTRA-1 Triacs TH6 & MOV6 Controls Right Auger Triac Maps for ULTRA-2Liquid AUTO-FILL Board ULTRA-2 Triacs Input and Output Chart ULTRA-1 41084 Input and Output Chart ULTRA-2 41084 41084
Related manuals
Manual 14 pages 46.12 Kb Manual 22 pages 47.89 Kb Manual 17 pages 28.06 Kb Manual 22 pages 35.42 Kb

ULTRA-1 specifications

The Bunn ULTRA-1 is a state-of-the-art coffee brewing system designed for commercial use, offering an unmatched combination of speed, efficiency, and flavor extraction. This single-serve coffee brewer is tailored for businesses that require high-quality coffee brews in a fast-paced environment, such as cafes, restaurants, and office kitchens.

One of the standout features of the Bunn ULTRA-1 is its ability to brew up to 14 different cup sizes, accommodating various customer preferences. This flexibility allows operators to serve everything from small espresso shots to larger coffee servings, making it a versatile addition to any beverage-serving establishment. At the heart of this brewing system is Bunn's patented brewing technology, which ensures precise water temperature and ideal brew time, optimizing the extraction process for a full-bodied flavor profile.

The ULTRA-1 is equipped with a large, easy-to-read LCD screen that provides real-time feedback, allowing users to monitor brewing progress, select cup sizes, and customize brewing parameters. This intuitive interface simplifies operation, reducing the learning curve for new staff members and enhancing overall efficiency during peak hours.

Another innovative aspect of the Bunn ULTRA-1 is its advanced thermal carafe system, which keeps brewed coffee at the optimal serving temperature without the need for a traditional warming plate. This technology helps preserve the coffee's rich flavor and aroma by preventing it from becoming bitter or stale due to prolonged exposure to heat.

The ULTRA-1 emphasizes ease of maintenance with its removable brew chamber and drip tray, allowing for quick cleaning and routine upkeep. Additionally, the brewer features a self-diagnostic system, alerting operators to any potential issues, further minimizing downtime.

From its sleek design to its robust construction, the Bunn ULTRA-1 combines aesthetics and durability, making it a reliable choice for any coffee-centric business. The compact design ensures it can fit on counters without taking up excessive space, while its stainless steel components provide longevity and resistance to wear and tear.

In conclusion, the Bunn ULTRA-1 stands out in the crowded market of commercial coffee brewers due to its advanced technology, versatility, and user-friendly features. It is designed to meet the demands of modern coffee service while ensuring that every cup brewed meets the highest standards for taste and quality.