TROUBLESHOOTING (cont.)
PROBLEM
Water is not hot (cont.)
Inconsistent beverage level in dis- penser
Spitting or excessive steaming
PROBABLE CAUSE
4. Tank Heater
1.Syphon System
2.Lime
CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral
1. Lime
CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral
2. Control Thermostat
REMEDY
Refer to Service - Tank Heater for testing procedures. See page 13
The brewer must be level or slightly lower in front to syphon properly.
Inspect the tank assembly for ex- cessive lime deposits. Delime as required.
Inspect tank assembly for exces- sive lime deposits. Delime as re- quired.
Refer to Service - Control Ther- mostat for testing procedures. See page 10
Dripping from sprayhead | 1. | Syphon System |
| 2. | Lime |
CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral
The brewer must be level or slightly lower in front to syphon properly.
Inspect the tank assembly for ex- cessive lime deposits. Delime as required.
Page 7 | 10860 | 090800 |
|
|