Bunn VP17B service manual ON/OFF Warmer Switch, Connect wire to Terminal #1 as follows

Page 12

SERVICE (cont.)

ON/OFF WARMER SWITCH

ONE LOWER WARMER

TWO WARMERS

THREE WARMERS

P1166.40

FIG. 6 ON/OFF WARMER SWITCHES

Location:

The ON/OFF warmer switch(es) are located on the front of the hood.

Test Procedure:

1.Disconnect the brewer from the power source.

2.Viewing the switch from the back, remove the white wire from the upper terminal and the black wire from the center terminal.

3.With a voltmeter, check the voltage across the white wire and the black wire. Connect the brewer to the power source. The indication must be:

a)100 volts ac for two wire 100 volt models.

b)120 volts ac for two wire 120 volt models.

4.Disconnect the brewer from the power source.

If voltage is present as described, reconnect the white wire and proceed to #5.

If voltage is not present as described, refer to the Wiring Diagrams and check the brewer wiring har- ness.

5.With the black wire removed, remove the wire from the lower terminal.

6.Check for continuity across the center and lower terminal with the switch in the "ON" (upper) posi- tion. Continuity must not be present when the switch is in the "OFF" (lower) position.

If continuity is present as described, reconnect the black wire to the center terminal and the remaining wire to the lower terminal.

If continuity is not present as described, replace the switch.

Removal and Replacement:

1.Remove the wires from the switch terminals.

2.Remove front end cap.

3.Compress the clips inside the hood and gently push the switch through the opening.

4.Push the new switch into the opening and spread the clips to hold switch in the hood.

5.Reinstall front end cap.

6.Refer to Fig. 7 when reconnecting the wires.

 

WHI to Lower Warmer

 

BLK to Terminal Block

 

or Tank Heater Switch

 

Terminal #1 (See Chart

 

Below)

 

P1918

Connect wire to Terminal #1 as follows:

Lower Warmer

WHI/RED

One Upper Warmer (Rear)

VIO

Two Upper or Side Warmers

 

(Front)

BRN/BLK

(Rear)

VIO

FIG. 7 ON/OFF SWITCH TERMINALS

Page 12

10860

061501

 

 

Image 12
Contents BUNNVP17 Post Office BOX SPRINGFIELD, IllinoisWarranty IntroductionUser Notices User Notices Electrical Requirements Initial SET-UPCleaning Coffee BrewingTroubleshooting ProblemProbable Cause RemedyTroubleshooting Water Temperature Probable Cause RemedyService Component AccessControl Thermostat Control ThermostatLimit Thermostat Limit ThermostatON/OFF Warmer Switch Connect wire to Terminal #1 as followsTank Heater Tank HeaterService Tank Heater Switch VP17B and early model VP17 Service Tank Heater Switch Warmer Elements Warmer Element TerminalsSchematic Wiring Diagram Volts AC 2 Wire Single PhaseSchematic Wiring Diagram VP17B-1/-2/-3