Bunn TWIN, ITB manual Spray OZ/M, Procedure to set the sprayhead flow rate

Page 22

PROGRAMMING THE BREWER (cont.)

PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)

*REFILL Range: 0 to 155

This function allows the operator to adjust the sensitiv- ity of the refill circuit. This is mainly a troubleshooting feature. Water in different geographical locations can have different conductivities. By adjusting the sensitivity of the refill circuit, this will allow the brewer to operate under various water conditions.

Procedure to set the sensitivity threshold of the refill circuit:

NOTE: Make sure the water in the tank is touching the refill probe.

1.Press and hold the right hidden switch until the display reads SET LANGUAGE. Press and release the right hidden switch until the display reads REFILL and shows a number on both sides of the word.

2.To adjust the threshold setting, press (-)to decrease or (+) to increase the setting.

NOTE: Always make sure that the number on the right is larger than the number on the left when water is in contact with the refill probe in the tank.

3.When finished, select DONE. This saves the new setting and advances to the next function screen (L) SPRAY OZ/M. To exit programming and return to the MAIN SCREEN, press ENABLE BREW ON/ OFF switch.

* SPRAY OZ/M

This function allows the operator to view or enter the actual flow rate coming out of each sprayhead. This is NOT used to control the actual flow rate, but to tell the internal processor how fast the water is flowing.

Procedure to set the sprayhead flow rate:

1.Press and hold the right hidden switch until the display reads SET LANGUAGE. Press and release the right hidden switch until the display reads SPRY OZ/M. The number represents what the brewer thinks is the flow rate out of that sprayhead.

2.If the actual flow rate of the sprayhead is known but is different than the number on the display, use the (-)and (+) to enter the correct flow rate.

3.Select DONE.

4.Repeat procedure for right side of Twins.

5.When finished, press and release DONE to advance to the next screen. To exit programming and return to the MAIN SCREEN, press ENABLE BREW ON/

OFF switch.

NOTE: If the flow rate is unknown, proceed to the CALIBRATE FLOW screen.

* BYPASS OZ/M (ICB & ICB Twins only)

This function allows the operator to view or enter the actual flow rate coming out of each bypass fitting. This is NOT used to control the actual flow rate, but to tell the internal processor how fast the water is flowing.

Procedure to adjust the bypass flow rate setting:

1.Press and hold the right hidden switch until the display reads SET LANGUAGE. Press and release the right hidden switch until the display reads BYPASS OZ/M. The number represents what the brewer thinks is the flow rate out of that bypass.

2.If the actual flow rate of the bypass is known but is different than the number on the display, use the (-)and (+) to enter the correct flow rate.

3.Select DONE.

4.Repeat procedure for right side of Twins.

5.When finished, press and release DONE to advance to the next screen. To exit programming and return to the MAIN SCREEN, press ENABLE BREW ON/ OFF switch.

NOTE: If the flow rate is unknown, proceed to the CALIBRATE FLOW screen.

* DILUTE OZ/M (ITB/ITCB only)

This function allows the operator to view or to enter the actual flow rate coming out of the dilution nozzle. This is NOT used to control the actual flow rate, but to tell the internal processor how fast the water is flowing.

Procedure to adjust the dilution flow rate setting:

1.Press and hold the right hidden switch until the display reads SET LANGUAGE. Press and release the right hidden switch until the display reads DILUTE OZ/M. The number represents what the brewer thinks is the flow rate out of the dilution nozzle.

Page 22

41581.2 091609

 

Image 22
Contents Post Office BOX SPRINGFIELD, Illinois Phone 217 529-6601 FAX 217BUNN-O-MATIC Commercial Product Warranty ITB ContentsItcb ICB Programming the BrewerICB Twin Programming the BrewerITB Programming Functions LevelItcb Itcb ITB Set Recipes TempsUsing a Recipe Card to load recipes Procedure to program the coffee nameProcedure to program the AD Procedure for setting Language Procedure for setting Brew LockoutSET Language Units Default Recipe Chart ICBDefault Assignments ICBITB/ITCB with Factory Sweetener VIEW/MODIFY Items ICBSweet Meter By Pressing SHOW,Setting Pulse Brew/PreInfusion Manual When finished, press the other batch size and repeat step #Setting Pulse Brew Easy Pulse Brew DONE?Setting Sweet Meter Optional on Itcb Setting Drip TimeProcedure Overview only Some Screens Omitted ICB ITB/ITCBSelect Done to disable that brew switch Procedure to select switch recipesProcedure to disable a Brew Switch No Name Coffee ItcbSET NEW Coffee Items Procedure for Setting the RecipeSET NEW Recipe Coffee only ICBMain Screen Enable ADSSET Temp ICB Master Temp Itcb Ready DegreeProcedure for enabling sanitation Range 0.0 to 72.0 hrs Enable SanitationEnable Sanitation From the NEW AD? screen, select CardAble Freshtimer Enable Energy SaverEnable Fresh Timer Hot Tea 0.5 to 8.0 hrsProcedure to adjust the dilution flow rate setting Procedure to set the sprayhead flow rateProcedure to adjust the bypass flow rate setting Spray OZ/MProcedure to calibrate the dilution flow rate Itcb Procedure to calibrate the sprayhead flow rateProcedure to calibrate the bypass flow rate ICB Calibrate FlowICB Series Programming Functions Level 2 Brew Counters Procedure to view/reset the brew countersITB/ITCB SET Recipe Temps Itcb only YESFactory Defaults Service NumberService Tools Asset NumberTroubleshooting Probable Cause TroubleshootingProblem RemedyProblem Probable Cause Remedy Ting Obstructions. Clear or replace Refill valve LongIf the left three digit number Control Board ON/OFF Switch Problem Probable CauseAutomatic refill will not operate or Ting Water flows into tank continuously Refill valveTo it is secure Heating Time TOO Long Lime buildup Been set for the current recipe Recipe settingsNo bypass water Bypass valve As requiredServer/dispenser Brew volume adjustmentInconsistent beverage level 90 psi 138 and 620 kPaSolenoids Tank heaters Remove and clean lime off tank HeatersFor proper extraction Vibrate during operationCoffee Water temperatureWeak beverage Type of paper filter Be used for proper extraction
Related manuals
Manual 36 pages 5.47 Kb

ITB, TWIN specifications

The Bunn TWIN,ITB is a remarkable coffee brewing system designed for commercial use, aimed at establishments that require a high volume of coffee while maintaining superior quality. This innovative brewer stands out through its dual brewing capability, allowing users to brew two different types of coffee simultaneously. This feature is particularly beneficial for cafes, restaurants, and other food service locations where diverse customer preferences must be met efficiently.

One of the main features of the Bunn TWIN,ITB is its advanced brewing technology. The system utilizes Bunn's patented brewing process, ensuring optimal coffee extraction and flavor profile every time. It employs a digitally controlled brew timer and state-of-the-art heating elements, providing precise temperature control essential for achieving the ideal brew. This technology allows for consistent results, ensuring that each cup meets the high standards expected in a commercial setting.

The design of the TWIN,ITB is user-friendly and intuitive. It includes an easy-to-read LED display that simplifies programming and monitoring of the brewing process. This streamlined interface enables baristas to adjust settings quickly and efficiently, significantly reducing wait times for customers. Additionally, the unit's low-profile design enables it to fit seamlessly into various kitchen layouts and countertops, optimizing valuable space.

Durability and reliability are at the forefront of the Bunn TWIN,ITB's construction. Built with high-quality materials, the brewer is designed to withstand the rigors of intense daily use. Its stainless-steel finish not only provides a sleek and professional appearance but also makes it easy to clean and maintain, ensuring longevity and excellent performance throughout its lifespan.

Furthermore, the TWIN,ITB features an impressive water capacity with a built-in hot water tank. This allows users to brew large batches of coffee without interruption and offers instant hot water for tea, soups, or other hot beverages. The efficient brewing system utilizes pre-infusion technology, which saturates the coffee grounds before extraction, enhancing the overall flavor and aroma of the brewed coffee.

In summary, the Bunn TWIN,ITB is an exceptional choice for any commercial establishment looking to provide high-quality coffee efficiently. Its dual brewing capabilities, advanced technologies, user-friendly design, durability, and additional features make it a valuable addition to any coffee service operation. Whether busy mornings or afternoon rushes, this brewer ensures that every cup of coffee meets the high standards of taste and quality that customers expect.