Bunn FMD-5, FMD-4 manual Problem Probable Cause Remedy

Page 8

TROUBLESHOOTING (cont.)

PROBLEM

PROBABLE CAUSE

REMEDY

Water is not hot (Cont.)

4. Tank Heater Switch

Refer to Service - Tank Heater Switch

 

 

for testing procedures. See page

 

 

52

 

5.

Heater Relay

 

6.

Control Board

Spitting or excessive steaming

1.

Lime build-up

CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water conditions. Excessive mineral build-up on stain- less steel surfaces can initiate cor- rosive reactions resulting in serious leaks.

Refer to Service - Heater Relay for testing procedures. See page 51

Refer to Service - Control Board for testing procedures. See page 20

Inspect the tank assembly for ex- cessive lime deposits. Delime as required.

2. Control Thermostat

Refer to Service - Control Thermo-

 

stat for testing procedures. See

 

page 26

Dripping from dispense tip

1. Lime build-up

 

CAUTION - Tank and tank compo-

 

nents should be delimed regularly

 

depending on local water conditions.

 

Excessive mineral build-up on stain-

 

less steel surfaces can initiate cor-

 

rosive reactions resulting in serious

 

leaks.

Inspect the tank assembly for ex- cessive lime deposits. Delime as required.

2.

Dispense Solenoid Valve

Remove the dispense solenoid valve

 

 

and clear any obstructions. Rebuild

 

 

or replace the valve if necessary. See

 

 

page 47

Water flows into tank continuously 1.

Control Board

Refer to Service - Control Board and

 

 

Probe for testing procedures. See

 

 

page 20

2.

Solenoid Valve (Inlet)

Refer to Service - Solenoid Valve

 

 

(Inlet) for testing procedures. See

 

 

page 49

8

42672 122209

 

Image 8
Contents FMD Series Phone 217 529-6601 FAX 217BUNN-O-MATIC Commercial Product Warranty Excluding regular maintenance itemsIntroduction Cleaning Required Regular Maintenance Problem Probable Cause Problem Product will not dispenseLevel Control Board and Probe FMD-1 RemedyProblem Probable Cause Remedy Troubleshooting Product overflows container Dispense Switch Install a regulator if necessary toExcess dust Fan Refer to Service Procedures. See42672 Component Access 20,23SERVICEcont Access PanelsLocation Service Auger Drive Components all ModelsTest Procedures Auger Motor Service Auger Drive ComponentsSpacer Auger Motor Hopper Base Dust Seal Washer Retainer Clip Panel RED to Control BoardRemove auger drive shaft bushing from hopper Rinse and dry each item thoroughlyBushing Panel Auger Drive Shaft Locknut Auger Motor BracketAuxillary Control Board FMD DBC-3 only Service Auxillary Control Board Disconnect the dispenser from the power sourceService Ballast all ModelsTest Procedure Power Supply Control BoardCheck that the RINSE/RUN switch is in the Rinse position Hopper Motor Control CircuitryUsing four #6-32 keps nuts Connectors on the control boardControl Board Control board to the component bracketControl Board Check that the rinse/run switch is in the run posi- tion Control Board Connectors Remove bulb from the tank Remove temperature probe from the tankLocation WHI to Main Control ThermostatBLK to Main If voltage is present as described, proceed to #7 Open the dispenser door and remove the bottom door coverIf voltage is present as described, proceed to #6 FMD DBC-2FD Digital Touch Control Switch FMD DBC-2,DBC-3FMD DBC-3 Digital Touch Control Switch ConnectorsEMI Filter 230 Volt FMD DBC-3 EMI FilterVacuum FAN all Models Test ProceduresDisconnect the black and white wires from the fan terminals Frother and Whipper Motor all Models except -2FD Frother and Whipper MotorFrother and Whipper Motor Will seat inside the whipper chamberHopper Drive Board FMD-1 only Hopper Drive BoardHopper Drive Board Terminals HOT/COLD Switch Optional for FMD DBC-3 Disconnect the wires from the switch terminalsTerminals Lamp Holder all Models Door Assy Upper Panel Lamp Holders Lower PanelLamp Starter and Socket Reconnect the violet wire to terminal Level Control Board and Level Probe FMD-1 onlyLevel Board Terminals Limit Thermostat all Models Limit ThermostatOverflow Protection Switch Rinse /RUN Switch all Models RINSE/RUN SwitchSolenoid Valve Cold Water Optional for FMD-2,-3,-4,-5 Cold Water Solenoid TerminalsSolenoid Valves Dispense all Models Dispense Solenoid Valves P1637.40 LocationHOT Water Dispense Solenoid Valve FMD-2FD,DBC-2FD,-3,DBC-3 Solenoid ValveSolenoid Valve Inlet all Models Inlet Solenoid ValveWHI or RED to Main BLK to Limit Wiring Harness Tank Heater all ModelsTank Heater Relay FMD-4,-5,120V Dispensers only BRN/BLK from WHI from Main HarnessTank Heater Switch all Models Tank Heater SwitchRemove and discard the transformer Disconnected from the main wiring harnessTransformer all Models Q1 & MOV1 Controls Left Whipper Motor Q2 & MOV3 Controls Center Whipper MotorQ5 & MOV4 Controls Right Whipper Motor Q7 & MOV2 Controls Refill ValveSchematic Wiring Diagram FMD-1 BLKSchematic Wiring Diagram FMD-1A WHI-16Schematic Wiring Diagram FMD-2 Schematic Wiring Diagram FMD-2A Schematic Wiring Diagram FMD DBC-2 Freeze Dried W/HOT Water Schematic Wiring Diagram FMD-2FD 42672 42672 42672 42672 Schematic Wiring Diagram FMD DBC-3 With HOT Water Dispense Schematic Wiring Diagram Fmda DBC-3 With HOT Water Dispense 42672 42672 42672 42672 Schematic Wiring Diagram FMD-5A