SERVICE (cont.)

CONTROL THERMOSTAT - FMD-4 & FMD-5

 

J1

P2635

J2

 

FIG. 9 CONTROL THERMOSTAT

 

Location

 

The control thermostat is located at the upper left rear of the dispenser housing.

Test Procedure

1.Disconnect the dispenser from the power source.

2.Disconnect the black wire of the control thermo- stat from the black lead from the limit thermostat.

3.Remove bulb from the tank.

4.Check the voltage across black wire on the control thermostat and the white or red wire on the tank heater with the tank heater switch in the “ON” lower position with a voltmeter. Connect the dis- penser to the power source. The indication must be:

a)120 volts ac for two wire 120 volt models.

b)208 volts ac for three wire 120/208 volt models.

c)240 volts ac for three wire 120/240 volt models.

5.Disconnect the dispenser from the power source.

If voltage is present as described the control thermo- stat is operating properly. Reinstall bulb into the tank. If voltage is not present as described, replace the thermostat.

Removal and Replacement.

1.Remove the thermostat capillary bulb by firmly pulling-up on the capillary at the tank lid. This will disengage the grommet from the tank lid.

2.Loosen the two #6-32 screws securing the ther- mostat to the front tank mounting bracket.

3.Disconnect the wires from the thermostat.

4.Remove thermostat and remove the screws and spacers from the thermostat.

5.Discard thermostat.

6.Install two spacers and two #6-32 screws on the new thermostat.

7.Position the thermostat on the botttom side of the front tank mounting bracket and tighten the two #6-32 screws.

8.Slide the grommet to the line 4.5" above the bulb on the new capillary tube.

9.Insert the capillary bulb through the hole in the tank lid and press the grommet firmly and evenly so that the groove in the grommet fits into the tank lid.

10.Carefully bend the capillary tube so that the tube and bulb inside the tank are in the vertical position and away from any electrical connections.

11.Refer to Fig. 10 and reconnect the wires.

NOTE - The capillary tube must be clear of any electri- cal termination and not kinked.

BLK from Limit

Thermostat

BLK from Tank

Heater Switch

P1668

FIG. 10 THERMOSTAT TERMINALS

19

35135 012103

 

Image 19
Contents Phone 217 529-6601 FAX 217 Post Office BOX SPRINGFIELD, IllinoisFMD-4 BUNN-O-MATIC Commercial Product WarrantyIntroduction User Notices28368.0000 00831.0000FMD-4 FMD-5 Plumbing Requirements Initial SET-UPElectrical Requirements Electrical HOOK-UPDispenser USE Liquid Level Control Rinse TimersInitial Fill & Heat Running a Rinse SequenceHopper Motor Speed Programing CleaningAdjustments Cold Beverage SET-UP OptionalDraining the HOT Water Tank Probable Cause TroubleshootingProblem Product will not dispenseProbable Cause Remedy Leaks Problem Probable CauseStat for testing procedures. See Dripping from dispense tip Lime build-upTip with a thermometer. Reading Product overflows container Dispense SwitchWeak product Water Temperature Refer to Operation Rinse Timer. SeeTroubleshooting Problem Auger Drive Components FMD-4 ServiceComponent Access ContentsSpacer Auger Motor Hopper Base Dust Seal Washer Hopper LidRetainer Clip Panel To the rear of the auger motor mounting panel Auger Drive Components FMD-4Location Hopper Dust Seal Auger Drive Components FMD-4 & FMD-5Bushing Panel Auger Drive Shaft LocknutRemove dust seal 17 from auger motor Ballasts FMD-4 & FMD-5 Refer to and reconnect the wiresLocation Control ThermostatControl Board Control BoardService Control Board Connectors FMD-4 Dispense Switchs FMD-4 & FMD-5FMD-5 Dispense Switch Terminals Dispense SwitchesFAN FANComponents Frother and Whipper Motor FMD-4 shown & FMD-5Whipper Motor Terminals INCREASE/DECREASE Switch INCREASE/DECREASE SwitchLamp Holders Lamp Replacement Refer to FigDoor Assy Upper Panel Lamp Holders Lower Panel Lamp Starter and Socket Refer to Location Lamp Replacement Refer toLimit Thermostat Limit ThermostatBLK from Main Harness BRN/BLK to RINSE/RUN SwitchBoard J2-3 HOT/COLD Switch HOT/COLD Switch OptionalCold Water Solenoid Valve Solenoid Valve Cold Water OptionalDispense Solenoid Valve Dispense Solenoid Valve Terminals Solenoid Valve Dispense FMD-4 & FMD-5Inlet Solenoid Valve Solenoid Valve InletMain Harness Thermostat Tank HeaterTank Heater Switch Pull component bracket out the front of the dis Tank Heater Relay 120V Dispensers onlyIf the resistance measures as described, proceed to step WHI/GRN from TransformerRemove and discard the transformer WHI from BLK from Main HarnessSchematic Wiring Diagram FMD-4 Single PHASE, 60HZ Schematic Wiring Diagram FMD-5 Single PHASE, 60HZ
Related manuals
Manual 71 pages 4.56 Kb Manual 29 pages 51.18 Kb

FMD-4, FMD-5 specifications

The Bunn FMD-5 is a state-of-the-art coffee dispenser designed specifically for high-volume coffee brewing situations. This machine is ideal for restaurants, convenience stores, and other establishments that require an efficient and reliable coffee dispensing solution.

One of the primary features of the Bunn FMD-5 is its ability to brew and serve fresh, hot coffee with exceptional speed. The unit is capable of dispensing up to five gallons of coffee per hour, making it an ideal choice for busy environments where customer demand is high. The system utilizes a digital brewer control that allows for precise brewing temperatures and times, ensuring consistency in flavor and quality.

The FMD-5 also incorporates advanced technologies to streamline the brewing process. It features a programmable control panel that allows users to adjust settings based on their specific needs. This includes the ability to set brew cycles, control brew levels, and even program different brew strengths. The easy-to-read digital display shows real-time information, making it simple for operators to monitor the brewing process.

Another notable characteristic of the Bunn FMD-5 is its compact and space-saving design. Despite its robust brewing capacity, the unit is designed to fit easily in various retail and foodservice environments. The machine is also built with durable materials, ensuring longevity and reliability under heavy usage.

For maintenance, the FMD-5 is designed with user convenience in mind. It features removable components and accessible areas for easy cleaning and routine maintenance. Users can also benefit from preventative maintenance features that monitor the machine’s performance, alerting operators to any potential issues before they escalate.

In terms of versatility, the Bunn FMD-5 can accommodate different brewing systems and coffee types, allowing users to customize their offerings based on customer preferences. It supports pre-ground coffee and can also be adapted for different brewing styles, enhancing its usability in various coffee service environments.

Overall, the Bunn FMD-5 is an impressive combination of speed, efficiency, and flexibility, making it an excellent choice for any operation that demands high-quality coffee with minimal wait time. Whether you are serving a morning rush of customers or maintaining a steady stream of coffee through the day, the Bunn FMD-5 stands out as a reliable and efficient coffee dispensing solution.