Bunn FMD-5 Initial SET-UP, Electrical Requirements, Electrical HOOK-UP, Plumbing Requirements

Page 4

INITIAL SET-UP

1.Locate the drip tray assembly inside the dispenser door.

2.Remove the drip tray and the drip tray cover and set them aside.

ELECTRICAL REQUIREMENTS

CAUTION - The dispenser must be disconnected from the power source until specified in Initial Set-Up.

The 120 volt version of this dispenser has an attached cordset and requires 2-wire, grounded service rated 120 volts ac, 15 amp, single phase, 60 Hz. The mating connector must be a NEMA 5-15R.

The 120/208 and the 120/240 versions of this dispenser has an attched cordset. The mating connector must be a NEMA 14-20R.

(Refer to the dispenser’s dataplate for exact voltage requirement.)

ELECTRICAL HOOK-UP

CAUTION – Improper electrical installation will damage electronic components.

1.An electrician must provide electrical service as specified.

2.Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.

3.Open the front door of the dispenser and place the heater switch in the “OFF” (upper position).

4.Connect the dispenser to the power source.

5.If plumbing is to be hooked-up later be sure the dispenser is disconnected from the power source. If plumb- ing has been hooked-up, the dispenser is ready for Initial Fill & Heat.

PLUMBING REQUIREMENTS

This dispenser must be connected to a cold water system with operating pressure between 20 and 100 psi (138 and 690 kPa). This water source must be capable of producing a minimum flow rate of 4.5 fluid ounces (133.1 ml) per second. A shut-off valve should be installed in the line before the dispenser. Install a regulator in the line when pressure is greater than 100 psi (690 kPa) to reduce it to 50 psi (345 kPa). The water inlet fitting is 38" flare.

NOTE - At least 18 inches of an FDA approved flexible beverage tubing, such as reinforced braided polyethylene or silicone, before the dispenser will facilitate movement to clean the countertop. It can be purchased direct from Bunn-O-Matic (part number 00327-0000). Bunn-O-Matic does not recommend the use of a saddle valve to install the dispenser. The size and shape of the hole made in the supply line by this type of device may restrict water flow.

This equipment must be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanita- tion Manual of the Food and Drug Administration (FDA).

PLUMBING HOOK-UP

1.Flush the water line and securely attach it to the flare fitting on the bottom of the dispenser.

2.Turn-on the water supply.

4

35135 012103

 

Image 4
Contents Post Office BOX SPRINGFIELD, Illinois Phone 217 529-6601 FAX 217BUNN-O-MATIC Commercial Product Warranty IntroductionUser Notices FMD-428368.0000 00831.0000FMD-4 FMD-5 Initial SET-UP Electrical RequirementsElectrical HOOK-UP Plumbing RequirementsLiquid Level Control Rinse Timers Initial Fill & HeatRunning a Rinse Sequence Dispenser USECleaning AdjustmentsCold Beverage SET-UP Optional Hopper Motor Speed ProgramingDraining the HOT Water Tank Troubleshooting ProblemProduct will not dispense Probable CauseProbable Cause Remedy Problem Probable Cause Stat for testing procedures. SeeDripping from dispense tip Lime build-up LeaksProduct overflows container Dispense Switch Weak product Water TemperatureRefer to Operation Rinse Timer. See Tip with a thermometer. ReadingTroubleshooting Problem Service Component AccessContents Auger Drive Components FMD-4Spacer Auger Motor Hopper Base Dust Seal Washer Hopper LidRetainer Clip Panel To the rear of the auger motor mounting panel Auger Drive Components FMD-4Location Auger Drive Components FMD-4 & FMD-5 Bushing Panel Auger Drive ShaftLocknut Hopper Dust SealRemove dust seal 17 from auger motor Refer to and reconnect the wires Ballasts FMD-4 & FMD-5Control Thermostat LocationControl Board Control BoardService Control Board Connectors FMD-4 Dispense Switchs FMD-4 & FMD-5FMD-5 Dispense Switches Dispense Switch TerminalsFAN FANFrother and Whipper Motor FMD-4 shown & FMD-5 ComponentsWhipper Motor Terminals INCREASE/DECREASE Switch INCREASE/DECREASE SwitchLamp Holders Lamp Replacement Refer to FigDoor Assy Upper Panel Lamp Holders Lower Panel Lamp Replacement Refer to Lamp Starter and Socket Refer to LocationLimit Thermostat Limit ThermostatBLK from Main Harness BRN/BLK to RINSE/RUN SwitchBoard J2-3 HOT/COLD Switch Optional HOT/COLD SwitchSolenoid Valve Cold Water Optional Cold Water Solenoid ValveDispense Solenoid Valve Solenoid Valve Dispense FMD-4 & FMD-5 Dispense Solenoid Valve TerminalsSolenoid Valve Inlet Inlet Solenoid ValveTank Heater Main Harness ThermostatTank Heater Switch Pull component bracket out the front of the dis Tank Heater Relay 120V Dispensers onlyIf the resistance measures as described, proceed to step Transformer Remove and discard the transformerWHI from BLK from Main Harness WHI/GRN fromSchematic Wiring Diagram FMD-4 Single PHASE, 60HZ Schematic Wiring Diagram FMD-5 Single PHASE, 60HZ
Related manuals
Manual 71 pages 4.56 Kb Manual 29 pages 51.18 Kb

FMD-4, FMD-5 specifications

The Bunn FMD-5 is a state-of-the-art coffee dispenser designed specifically for high-volume coffee brewing situations. This machine is ideal for restaurants, convenience stores, and other establishments that require an efficient and reliable coffee dispensing solution.

One of the primary features of the Bunn FMD-5 is its ability to brew and serve fresh, hot coffee with exceptional speed. The unit is capable of dispensing up to five gallons of coffee per hour, making it an ideal choice for busy environments where customer demand is high. The system utilizes a digital brewer control that allows for precise brewing temperatures and times, ensuring consistency in flavor and quality.

The FMD-5 also incorporates advanced technologies to streamline the brewing process. It features a programmable control panel that allows users to adjust settings based on their specific needs. This includes the ability to set brew cycles, control brew levels, and even program different brew strengths. The easy-to-read digital display shows real-time information, making it simple for operators to monitor the brewing process.

Another notable characteristic of the Bunn FMD-5 is its compact and space-saving design. Despite its robust brewing capacity, the unit is designed to fit easily in various retail and foodservice environments. The machine is also built with durable materials, ensuring longevity and reliability under heavy usage.

For maintenance, the FMD-5 is designed with user convenience in mind. It features removable components and accessible areas for easy cleaning and routine maintenance. Users can also benefit from preventative maintenance features that monitor the machine’s performance, alerting operators to any potential issues before they escalate.

In terms of versatility, the Bunn FMD-5 can accommodate different brewing systems and coffee types, allowing users to customize their offerings based on customer preferences. It supports pre-ground coffee and can also be adapted for different brewing styles, enhancing its usability in various coffee service environments.

Overall, the Bunn FMD-5 is an impressive combination of speed, efficiency, and flexibility, making it an excellent choice for any operation that demands high-quality coffee with minimal wait time. Whether you are serving a morning rush of customers or maintaining a steady stream of coffee through the day, the Bunn FMD-5 stands out as a reliable and efficient coffee dispensing solution.