Bunn service manual Frother and Whipper Motor FMD-4 shown & FMD-5, Components

Page 26

SERVICE (cont.)

FROTHER AND WHIPPER MOTOR - FMD-4 (shown) & FMD-5

J1

J2

J4

J3

J1

J2

J4

J3

P2635

FIG. 17 FROTHER AND WHIPPER MOTOR

Location:

The frothers are located behind the dispenser door, mounted on the front panel inside the whipper cham- ber.

The whipper motors are located on the back side of the whipper motor mounting panel.

Test Procedure:

1.Disconnect the dispenser from the power source.

2.Disconnect the red and white wires (FMD-1 & FMD-2 left motor) or orange and white wires (FMD-2 right motor) of the main harness from the black leads of the motor.

3.Press and hold the dispense switch and check the voltage across the disconnected harness wires with a voltmeter. Connect the dispenser to the power source. The reading must be:

a)120 volts ac for two wire 120 volt models.

b)120 volts ac for three wire 120/208 volt or 120/ 240 volt models.

4. Disconnect the dispenser from the power source.

If voltage is present as described, replace the motor. If voltage is not present as described, refer to the wir- ing diagrams and check the dispenser wiring harness.

 

 

 

 

10

 

 

 

 

 

 

 

 

 

7

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

4

11

12

13

9

8

6

5

3

 

 

 

 

 

P2628

 

 

 

 

 

 

 

 

FIG. 18 MIXING/WHIPPER CHAMBER

 

 

 

 

COMPONENTS

 

 

 

1.

Steam Collector

8.

Nut

2.

Mixing Chamber

9.

Slinger

3.

Dispense Tip

10.

Motor Assy.

4.

Whipper Chamber

11.

Fan

5.

O-Ring

12.

Vacuum Hose

6.

Frother

13.

Baffle

7.Receptacle w/Seal

Removal, Cleaning & Replacement (Refer to Fig. 18):

1.Open the dispenser door and raise the top front cover.

2.Lift the front edge of the each hopper assembly over the tab on the hopper support panel and slide each hopper assembly out the front of the dispenser. Set aside for reassembly.

3.Remove the four #8-32 screws securing the hop- per support panel to auger motor mounting panel and the whipper motor mounting panel. Set aside for reassembly.

26

35135 012103

 

Image 26
Contents Post Office BOX SPRINGFIELD, Illinois Phone 217 529-6601 FAX 217User Notices BUNN-O-MATIC Commercial Product WarrantyIntroduction FMD-4FMD-4 FMD-5 00831.000028368.0000 Electrical HOOK-UP Initial SET-UPElectrical Requirements Plumbing RequirementsRunning a Rinse Sequence Liquid Level Control Rinse TimersInitial Fill & Heat Dispenser USECold Beverage SET-UP Optional CleaningAdjustments Hopper Motor Speed ProgramingDraining the HOT Water Tank Product will not dispense TroubleshootingProblem Probable CauseProbable Cause Remedy Dripping from dispense tip Lime build-up Problem Probable CauseStat for testing procedures. See LeaksRefer to Operation Rinse Timer. See Product overflows container Dispense SwitchWeak product Water Temperature Tip with a thermometer. ReadingTroubleshooting Problem Contents ServiceComponent Access Auger Drive Components FMD-4Retainer Clip Panel Hopper LidSpacer Auger Motor Hopper Base Dust Seal Washer Location Auger Drive Components FMD-4To the rear of the auger motor mounting panel Locknut Auger Drive Components FMD-4 & FMD-5Bushing Panel Auger Drive Shaft Hopper Dust SealRemove dust seal 17 from auger motor Refer to and reconnect the wires Ballasts FMD-4 & FMD-5Control Thermostat LocationControl Board Control BoardService Control Board Connectors FMD-5 Dispense Switchs FMD-4 & FMD-5FMD-4 Dispense Switches Dispense Switch TerminalsFAN FANFrother and Whipper Motor FMD-4 shown & FMD-5 ComponentsWhipper Motor Terminals INCREASE/DECREASE Switch INCREASE/DECREASE SwitchDoor Assy Upper Panel Lamp Holders Lower Panel Lamp Replacement Refer to FigLamp Holders Lamp Replacement Refer to Lamp Starter and Socket Refer to LocationLimit Thermostat Limit ThermostatBoard J2-3 RINSE/RUN SwitchBLK from Main Harness BRN/BLK to HOT/COLD Switch Optional HOT/COLD SwitchSolenoid Valve Cold Water Optional Cold Water Solenoid ValveDispense Solenoid Valve Solenoid Valve Dispense FMD-4 & FMD-5 Dispense Solenoid Valve TerminalsSolenoid Valve Inlet Inlet Solenoid ValveTank Heater Main Harness ThermostatTank Heater Switch If the resistance measures as described, proceed to step Tank Heater Relay 120V Dispensers onlyPull component bracket out the front of the dis WHI from BLK from Main Harness TransformerRemove and discard the transformer WHI/GRN fromSchematic Wiring Diagram FMD-4 Single PHASE, 60HZ Schematic Wiring Diagram FMD-5 Single PHASE, 60HZ
Related manuals
Manual 71 pages 4.56 Kb Manual 29 pages 51.18 Kb

FMD-4, FMD-5 specifications

The Bunn FMD-5 is a state-of-the-art coffee dispenser designed specifically for high-volume coffee brewing situations. This machine is ideal for restaurants, convenience stores, and other establishments that require an efficient and reliable coffee dispensing solution.

One of the primary features of the Bunn FMD-5 is its ability to brew and serve fresh, hot coffee with exceptional speed. The unit is capable of dispensing up to five gallons of coffee per hour, making it an ideal choice for busy environments where customer demand is high. The system utilizes a digital brewer control that allows for precise brewing temperatures and times, ensuring consistency in flavor and quality.

The FMD-5 also incorporates advanced technologies to streamline the brewing process. It features a programmable control panel that allows users to adjust settings based on their specific needs. This includes the ability to set brew cycles, control brew levels, and even program different brew strengths. The easy-to-read digital display shows real-time information, making it simple for operators to monitor the brewing process.

Another notable characteristic of the Bunn FMD-5 is its compact and space-saving design. Despite its robust brewing capacity, the unit is designed to fit easily in various retail and foodservice environments. The machine is also built with durable materials, ensuring longevity and reliability under heavy usage.

For maintenance, the FMD-5 is designed with user convenience in mind. It features removable components and accessible areas for easy cleaning and routine maintenance. Users can also benefit from preventative maintenance features that monitor the machine’s performance, alerting operators to any potential issues before they escalate.

In terms of versatility, the Bunn FMD-5 can accommodate different brewing systems and coffee types, allowing users to customize their offerings based on customer preferences. It supports pre-ground coffee and can also be adapted for different brewing styles, enhancing its usability in various coffee service environments.

Overall, the Bunn FMD-5 is an impressive combination of speed, efficiency, and flexibility, making it an excellent choice for any operation that demands high-quality coffee with minimal wait time. Whether you are serving a morning rush of customers or maintaining a steady stream of coffee through the day, the Bunn FMD-5 stands out as a reliable and efficient coffee dispensing solution.