Extron electronic RGB 201 Rxi manual Error responses, Timeout, Using the command/response table

Page 35

Error responses

When the interface receives a valid SIS command, it executes the command and sends a response to the host device. If the interface is unable to execute the command because the command is invalid or it contains invalid parameters, it returns an error response to the host.

The error response codes and their descriptions are as follows:

E10 – Invalid command

E13 – Invalid value (the number is out of range/too large)

Timeout

Pauses of 10 seconds or longer between command ASCII characters result in a timeout. The command operation is aborted with no other indication.

Using the command/response table

The command/response table is on the next page. Lower case letters are allowed in the command field only as indicated. Symbols are used throughout the table to represent variables in the command/response fields. Command and response examples are shown throughout the table. The ASCII to HEX conversion table below is for use with the command/response table.

Symbol definitions

] = CR/LF (carriage return/line feed) (0x0D 0A)

= space

X@

=

Shift control range

-127 to +127

X#

= Controller firmware version (listed to two decimal

 

 

 

places, “x.xx”)

X$

=

xxx.xx

Frequency in Hz or kHz

X^

=

Part number

 

ASCII to HEX Conversion Table

Space

.

RGB 201 Rxi Universal Interface • Remote Control

3-3

Image 35
Contents Universal Video Interface with Audio RGB 201 RxiPrecautions FCC Class a Notice 安全须知 中文Page RGB 201 Rxi Universal Interface Quick Start Guide Quick Start Guide RGB 201 RxiFor details about SIS Commands and the control Switch PositionConnect an RS-232 device To this connector for Remote control. SeeTable of Contents Table of Contents, cont’d One RGB 201 Rxi Universal Interface Introduction Introductionduction,cont’d About this ManualAbout the RGB 201 Rxi RGB 201 R xi Universal Interface Introduction FeaturesIntroduction, cont’d Two RGB 201 Rxi Universal Interface Installation and Operation Instaltal lationandandOperation,cont’d Installation OverviewRGB 201 Rxi Universal Interface Installation and Operation Internal ConfigurationSync polarity jumpers Installation and Operation, cont’dVideo clamping jumper Internal sync DIP switches RsGsBsRGB 201 R xi Universal Interface Installation and Operation Under-desk mounting Installation and Operation, cont’d Mounting the InterfaceTabletop placement Through-desk mounting Through-desk mountingInstallation and Operation, cont’d UL guidelines for rack mounting Rack mounting procedureRack mounting Rack mounting Pin HD female connector Rear Panel Connections and SwitchesConnect the cables to five BNCs Audio output connector Connect an audioDdsp Spare Remote connector pinout Front panel controls and indicators Many projectors store centering information in their own Centering controlsScan rate indication Centering memoryLCD display LCD screen backlightIf the image is not displayed correctly TroubleshootingIf the image does not appear or there is no sound If the image is not correctly centered If the interface does not respond to controlsThree Host-to-interface communications RGB 201 Rxi Universal Interface Remote ControlRemoteControl,cont’d Simple Instruction Set ControlSymbol definitions Error responsesTimeout Using the command/response tableRemote Command/response table for SIS commandsControl Software for Windows Installing the softwareUsing the software RGB 201 R xi Universal Interface Remote ControlUsing the help system Remote Control, cont’dAAppendix Video output ReferencerenceInformation,cont’d SpecificationsVideo Video inputControl/remote interface AudioAudio input Audio outputIncluded Parts Part number Reference Information, cont’dIncluded Parts GeneralAdapter cables with Audio Part number Optional AccessoriesAccessories Part number CablesBNC cables Part number USA, Canada, South America Japan Central America Extron’s WarrantyExtron Electronics. All rights reserved