Installation and Operation, cont’d
J9 H Sync
J20 V Sync
J21 Enable
Sync
J23
ON | SW2 |
1 2 | |
1 | Blue |
1Red
J28 | J11 | 1 |
| 2 | |
|
| 3 |
J22
Connector
Figure 2-2 — Location of jumpers and DIP switches
Sync polarity jumpers
The interface is factory configured for the output sync to follow the input sync. To force positive or negative sync, reconfigure the jumper as follows:
1. Locate J9, J20, and J21 on the printed circuit board.
2. For sync follow (output sync polarity identical to the input sync), ensure that the jumper is removed from jumper block J21.
3. For positive or negative sync, ensure that a jumper is installed in jumper block J21 and configure J9 and J20 as follows:
a. Horizontal sync —
For positive sync, install a jumper in block J9.
For negative sync, remove the jumper from block J9.
b. Vertical sync —
For positive sync, install a jumper in block J20.
For negative sync, remove the jumper from block J20.