Bunn CDBC APS-DV, CDBCF-DV, CDBC-MV, CDBC-DV, CDBCF APS-MV, CDBCF-MV Schematic Wiring Diagram Cdbc MV

Page 36

SCHEMATIC WIRING DIAGRAM CDBC MV

L1

N L2

GRN

 

 

 

 

 

 

 

 

THERMAL

TANK HEATER

 

THERMAL

 

 

 

 

 

 

 

 

BLU-14

 

 

 

 

 

 

 

 

 

 

 

FUSE

 

 

 

FUSE

 

 

 

LIMIT

 

 

 

 

BLK-14

TANK HEATER WHI-14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THERMOSTAT

 

 

 

 

 

 

 

 

 

 

 

BLK-14

20

BLK-14

BLU-14

 

 

 

 

BLK-14

 

 

 

RED-14

 

 

AMP

 

 

 

 

 

 

 

 

WHI-14

 

 

 

WHI

 

"KEEP WARM" HEATER

 

 

 

 

 

 

 

WHI

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

BREW STATION WARMER

 

 

 

 

 

 

 

 

 

WHI/RED

(CONTROLLED BY ON/OFF SW)

 

WHI

 

 

 

COUNTER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REFILL

 

 

 

(OPTIONAL)

 

 

 

 

 

 

 

 

J1-1

 

BLK

 

 

 

 

 

 

WHI/BLU

 

SOL

WHI

C

 

BLK

 

 

 

 

 

DISPENSE

 

 

 

J1-2

 

 

 

 

 

 

 

 

 

 

O

COM

BLU-14

 

 

WHI/GRN

SOL

 

 

 

 

WHI

N

N.O.

BLK-14

 

 

 

 

 

 

 

 

 

 

T

WHI

 

 

 

 

 

 

 

 

 

 

WHI

R

J1-1

 

 

 

 

 

 

WARMER ASSY "A"

 

 

 

O

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

 

BRN/BLK

 

 

BRN/BLK

P2

 

BRN/BLK

FRONT WARMER

 

P1

 

WHI

P

 

 

 

 

 

WHI

 

 

 

 

 

 

 

 

 

 

J1-5

 

WHI/BLU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

WHI/RED

 

 

 

 

(SEE TABLE BELOW FOR USAGE)

W

 

P1, P2, &

 

 

 

 

 

 

 

 

 

 

YEL

 

 

 

 

H

 

P3 ARE

B

 

 

WHI/VIO

 

 

 

P3

 

 

REAR WARMER

I

 

 

 

 

 

VIO

 

VIO

 

PINS OF A

O

 

 

VIO

 

 

 

 

 

 

 

POLARIZED

A

 

 

WHI/GRN

 

 

 

 

 

 

 

 

 

J1-10

 

 

 

 

 

 

 

 

 

 

THREE-PIN

R

 

CONTROL PANEL ASSY

 

 

 

WARMER ASSY "B"

 

 

D

 

 

 

 

 

 

 

CONNECTOR.

 

J2-1

 

BREW SW

LT FRNT SW

LT REAR SW

YEL

P2

 

YEL

FRONT WARMER

WHI

P1

 

WHI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON/OFF SW

TOP FRNT SW

TOP REAR SW

 

 

(SEE TABLE BELOW FOR USAGE) W

 

 

 

 

 

 

 

 

 

 

P3

 

 

REAR WARMER

H

 

 

 

 

J2-6

 

 

 

 

WHI/VIO

 

WHI/VIO

I

 

 

 

 

 

HIDDEN SW

RT REAR SW

RT FRNT SW

 

 

 

 

 

 

 

 

 

 

 

 

 

WARMER WIRING REFERENCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(ALL CONFIGURATIONS INCLUDE BREW STATION WARMER)

J2-11

 

STATIC

(NOTE – ALL WARMERS ARE NOT

 

SHIELD

AVAILABLE ON ALL MODELS!)

 

J3-1

PNK

 

GRN

 

 

 

 

WHI

LEVEL

J3-4

BLK

 

PROBE

 

 

 

 

t°

29685.0000A 4/99 ©1999 BUNN-O-MATIC CORPORATION

 

LEFT

TOP

RIGHT

WITH TOP WARMERS

"A"

WITH LEFT WARMERS

"B"

WITH RIGHT WARMERS

"A"

WITH LEFT & RIGHT WARMERS

"B"

"A"

WITH LEFT & TOP WARMERS

"B"

"A"

WITH RIGHT & TOP WARMERS

"A"

"B"

 

 

 

 

120V AC 2 WIRE

120/208V AC 3 WIRE 120/240V AC 3 WIRE SINGLE PHASE

Page 36

29707 112801

 

Image 36
Contents DIS Version Introduction TWO Warmer Brewers Three Warmer BrewersAPS Brewers CDBCF-DV Brewers Cdbc LPTC-DV BrewersNo Warmer Brewers ONE Warmer BrewersElectrical Requirements 1425W VersionElectrical HOOK-UP Models CDBC-MV & CDBC-APS MV Cleaning Plumbing RequirementsInitial SET-UP Coffee BrewingON/OFF Switch Brew SwitchAdditional Warmer Switches Ready IndicatorAdjustments & Optional Settings Setting Brew TemperatureDisplaying Brew Temperature Setting Brew LockoutWater Sensing Threshold Adjustment Procedure Troubleshooting Before troubleshooting this brewer, check for the followingTroubleshooting Refill Circuit Problem Probable CauseRemedy Troubleshooting Refill Circuit Heating Circuit Problem Water does not heat to proper tem- peratureTroubleshooting Heating Circuit Problem Probable CauseTank Heater Ings are takenProblem Probable Cause Remedy Brewing Circuit Problem Probable Cause Troubleshooting Brewing Circuit Consistently low beverage level Brew volumeDispenser Be made with sprayhead installed Brew cycle will not start Control board or dispense valveWater temperature Set-upinstructionsDripping from sprayhead Lime build up RequiredProblem Probable Cause Diagnostics Cause Things to CheckService When servicing, except when electrical tests are reComponent Access Service Disconnect the 11-pin connector from the control panelControl Board Switch Panel Dispense Valve Limit Thermostat Wiring Limit ThermostatTank Heaters Tank Heater Terminal Block Wiring Diagram Voltage Selector Switch Terminals Refill Valve Warmer Elements Warmer ElementsFuse HOLDER/FUSE Assembly MV models only Service Thermal Fuses MV models only Thermal FusesSchematic Wiring Diagram Cdbc DV Schematic Wiring Diagram Cdbc APS-DV Cdbcf APS/TC/LPTC-DV Schematic Wiring Diagram Cdbc MV Schematic Wiring Diagram Cdbc APS MV
Related manuals
Manual 2 pages 47.58 Kb

CDBCF-MV, CDBCF APS-DV, CDBCF APS-MV, CDBC-DV, CDBC-MV specifications

The Bunn CDBCF-DV is a distinguished coffee brewer designed for commercial use, ideal for establishments that demand high-quality coffee at a fast pace. This brewer is notable for its innovative design and advanced brewing technology, making it an essential asset for cafes, restaurants, and coffee shops.

One of the standout features of the Bunn CDBCF-DV is its dual-voltage capability. This versatility allows the brewer to operate efficiently on both 120V and 240V power sources, ensuring that it meets the needs of various establishments regardless of electrical setup. This adaptability makes it a favorite among coffee vendors looking to optimize performance without the inconvenience of electrical constraints.

The BDCBF-DV also boasts a large capacity, allowing it to brew up to 14 cups of coffee in a single cycle. This is facilitated by its large water tank and high brewing rate, which can produce coffee in just a matter of minutes. The ability to brew rapidly while maintaining quality is crucial in busy environments where time is of the essence.

Key to the Bunn CDBCF-DV's performance is its patented brewing system that utilizes a pre-infusion feature. This technology ensures that the coffee grounds are saturated before the brewing process begins, promoting optimal extraction of flavors and aromas. The result is a rich, well-balanced cup of coffee that delights patrons and encourages repeat business.

Another notable characteristic is the brewer's easy-to-use control interface. With simple dial settings, baristas can effortlessly adjust brew strength and temperature, ensuring consistency with every batch. The intuitive design minimizes training time for new staff and enhances overall workflow in commercial settings.

Durability and maintenance are critical in commercial coffee brewing equipment, and the Bunn CDBCF-DV excels in this area as well. Constructed with high-quality materials, it is built to withstand the rigors of daily use. Additionally, it features easily accessible parts for straightforward cleaning and servicing, reducing downtime and ensuring that the coffee remains fresh and delicious.

In summary, the Bunn CDBCF-DV is a versatile, efficient, and user-friendly coffee brewer loaded with innovative features aimed at delivering exceptional coffee quality. Its dual-voltage operation, large capacity, pre-infusion technology, and durable design make it an indispensable choice for businesses looking to enhance their coffee offerings and improve customer satisfaction. Whether you're a small cafe or a larger restaurant chain, the Bunn CDBCF-DV is engineered to meet your coffee brewing demands with excellence.